USER INSTRUCTIONS

10. oxygen depletion sensor

The fire is fitted with an oxygen sensitive pilot system that will act to cut off the gas supply to the fire should the oxygen in the room fall below its normal level. If the fire is turned off by this device, it usually indicates that there is a problem with the flue system, and this should be inspected by a qualified engineer. Do not attempt to use the fire until an engineer says it is safe to do so.

This device is not a substitute for an independently mounted carbon monoxide detector.

11. flame failure device

This is a safety feature incorporated in all GAZCO fires which automatically switches off the gas supply if the pilot light goes out and fails to heat the thermocouple.

12. running in

The surface coating on the coals used in your GAZCO fire will burn off during the first few hours of use, producing a harmless and temporary odour. This will disappear after a short period of use. If the odour persists, ask your installer for advice.

13. servicing

The fire must be serviced every 12 months by a qualified Gas Engineer. In all correspondence, always quote the fire type and serial number, which may be found on the data badge located on chain beneath the control valve.

14. ventilation

Any purpose provided ventilation should be checked periodically to ensure that it is free from obstruction.

15. installation details

To assist in any future correspondence, your installer should have completed the commissioning sheet at the front of this manual. In all correspondence always quote the Model Number and Serial Number.

10

Image 10
Contents Studio& Logic E-box Contents Pass Fail APPLIANCE COMMISSIONING CHECKLISTFLUE CHECK GAS CHECKLighting the Fire User InstructionsGeneral Turning the Fire OFFCleaning the logic-e box Cleaning the E-studioStudio Arrangement of Fuel BED Components AR1769 Logic E-BOX ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICSArrangEMENT of fuel bed Components Large Medium Small Pebble Layout Flame failure device Installation detailsOxygen depletion sensor RunningStudiomodels 8691CFCHUC Installation InstructionsTechnical Specification P8691CFCHUCFinish Arts Frame Holyrood SpanishOverall External Dimensions Plan View Flue and Chimney Requirements Site RequirementsFire Location Ventilation GAS SupplyAIR Vents Must not be Restricted Safety Precautions InstallationControl Upgrade Installation of the GAS SupplyInstallation of the Fire Cable Retention MethodFitting the Decorative Inner panel Screw Fixing MethodAR1931 Logic E-BOX arrangEMENT of fuel bed components AR1364 Pebble Layout Lighting the fire Installation / CommissioningCommissioning Servicing Servicing InstructionsServicing Requirements Studio & Logic E-BOX Servicing Instructions Fault Finding Charts Fault Finding Charts Ignition Lead Replacing PartsGeneral PiezoOds pilot unit Pilot injector Ignition electrode ThermocoupleMag unit Gas valveMain injector Spare parts list Logic E-BOX Spare parts list-E-STUDIOChanging between gas types Service Records