Stovax PR0741 manual Replacing Parts, General, Ignition Lead, Piezo

Page 28

SERVICING INSTRUCTIONS

REPLACING PARTS

1.GENERAL

1.1To service any of the following parts of the fire, it will be necessary to remove the burner unit from the firebox. To remove the burner refer to previous section SERVICING.

1.2The heat shield will need to be removed from the burner for servicing. To do this remove the five screws indicated in diagram 1 and slide the shield forward. Note: E-Studio only has three screws.

1

AR1370

2.IGNITION LEAD

2.1Undo the single screw that secures the left hand side of the control cover, Diagram 2.

2

AR0915

2.2To release the right-hand side of the control cover insert the narrow blade screwdriver into the slot shown in diagram 3, lever it gently and pull from the right-hand side at the same time. The cover will now come off, there is a small cylindrical metal spacer inside the cover, this must be kept and replaced on the fixing screw during re-assembly.

3

AR0916

2.3Disconnect the ignition lead from the gas valve and the pilot, Diagram 4 arrow A.

4

A

 

AR1371

 

 

 

2.4Replace with a new ignition lead following the same route as the old one. Replace the valve cover and refit the burner.

2.5Check the operation of the new ignition lead.

2.6Replace the fire frame.

3.piezo

3.1The piezo assembly used on this fire is not serviceable and is unlikely to fail. If a new piezo is required it will be necessary to change the gas valve, refer to section 5.

28

Image 28
Contents Studio& Logic E-box Contents APPLIANCE COMMISSIONING CHECKLIST FLUE CHECKPass Fail GAS CHECKUser Instructions GeneralLighting the Fire Turning the Fire OFFCleaning the logic-e box Cleaning the E-studioStudio Arrangement of Fuel BED Components AR1769 Logic E-BOX ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICSArrangEMENT of fuel bed Components Large Medium Small Pebble Layout Installation details Oxygen depletion sensorFlame failure device RunningInstallation Instructions Technical SpecificationStudiomodels 8691CFCHUC P8691CFCHUCFinish Arts Frame Holyrood SpanishOverall External Dimensions Plan View Flue and Chimney Requirements Site RequirementsFire Location Ventilation GAS SupplyAIR Vents Must not be Restricted Installation Control UpgradeSafety Precautions Installation of the GAS SupplyInstallation of the Fire Cable Retention MethodFitting the Decorative Inner panel Screw Fixing MethodAR1931 Logic E-BOX arrangEMENT of fuel bed components AR1364 Pebble Layout Lighting the fire Installation / CommissioningCommissioning Servicing Servicing InstructionsServicing Requirements Studio & Logic E-BOX Servicing Instructions Fault Finding Charts Fault Finding Charts Replacing Parts GeneralIgnition Lead PiezoOds pilot unit Pilot injector Ignition electrode ThermocoupleMag unit Gas valveMain injector Spare parts list Logic E-BOX Spare parts list-E-STUDIOChanging between gas types Service Records