Therma-Tru Smooth-Star manual Secure Frame in Rough Opening, Apply Sealant to Inactive Door Riser

Page 10

12

SECURE FRAME IN ROUGH OPENING

Using (12) #8 x 3" pan head screws, fasten frame to rough opening through pre-drilled holes in frame.

#8 x 3" Pan Head Screws

The sill's center screw needs to be installed three inches off center in the direction of the active panel.

#8 x 3" Pan Head Screws

The sill does not have pre-drilled holes. The screws used on the sill are installed through the sill cap base into the sill substrate. There is a v-groove in the sill cap base to assist in aligning the screw.

Sill Cap Base

13

APPLY SEALANT TO INACTIVE DOOR RISER

Apply a 1/4" continuous bead of clear sealant along length of inactive sill riser at locations shown.

Sealant

Inactive sill riser

9

Image 10
Contents Double Unit Assembly & Installation Screen sold separately Active Panel Inactive Panel Screw Chart Install Sill CAP Base If APPLICABLE, Install TOP-HUNG Screen TrackLAY Frame Components Onto Work Area Attach Sill to Jambs Attach Head to JambsDrip CAP Installation Apply Corner Pads to Sealing FINFrame Installation Apply Silicone Sealant to Sill and Fins SET Unit Into Rough OpeningLevel Sill Plumb Side JambsSecure Frame in Rough Opening Apply Sealant to Inactive Door RiserInstall Stationary Panel Install Anchor BlocksInstall Active Panel Adjust RollersInstall Active Interlock Attach Inactive InterlockInsert Panel Bumper Handle InstallationAttach Strike Plate Prep Door for Foot Bolt Install Sill CAP TOPAttach Foot Bolt Attach Jamb Cover Install Foot Bolt KeeperInsert Plugs Sliding Screen DoorActive panel edge Dia holes 1 deep Towards Page Finishing Instructions WEATHERPROOF, Finish and Maintain Jamb Extension InformationInterior Casing Attachment Sizing Information Door Handing Guide Patiodoorsystems