CANopen DSP 402 Implementation Guide
98
Object 0x606C: Velocity actual value
This object is represented in velocity units and is coupled with the velocity used as input to the velocity controller. The object is taken from either the position sensor or the velocity sensor. In UM=5 (single position loop), this object reflects the load and the motor value; in UM=4 (dual loop), object 0x606A determines which sensor is reflected.
Object description:
| Index |
| 606Ch |
| Name |
| Velocity actual value |
| Object code |
| VAR |
| Data type |
| INTEGER32 |
| Category |
| Mandatory |
Entry description: |
|
| |
|
|
|
|
| Access |
| Read only |
| PDO mapping |
| Yes |
| Value range |
| INTEGER32 |
| Default value |
| No |
Object 0x606D: Velocity window
This object monitors whether the required process velocity has been achieved after an eventual acceleration or deceleration (braking) phase. It is given in velocity units.
Object description:
| Index |
| 606Dh |
| Name |
| Velocity window |
| Object code |
| VAR |
| Data type |
| UNSIGNED16 |
| Category |
| Optional |
Entry description: |
|
| |
|
|
|
|
| Access |
| Read/write |
| PDO mapping |
| No |
| Value range |
| UNSIGNED16 |
| Default value |
| No |