CANopen DSP 402 Implementation Guide
35
Object 0x605E: Fault reaction option code
Object description:
| Index |
| 605Eh |
| Name |
| Fault reaction option code |
| Object code |
| VAR |
| Data type |
| INTEGER16 |
| Category |
| Optional |
Entry description: |
|
| |
|
|
|
|
| Access |
| Read/write |
| PDO mapping |
| No |
| Value range |
| INTEGER16 |
| Default value |
| 0 |
Data description: |
|
|
Value | Description |
Manufacturer specific | |
0 | Disable drive function |
1…4 | Not supported |
1…32,767 | Reserved |
Notes:
An attempt to set an unsupported value causes the transmission of abort code 0609 0030: Value exceeded.
All drive faults are considered fatal. When a fatal fault occurs, the drive is no longer able to control the motor, requiring that the drive be