Object 0x6075: Motor Rate Current
This value is taken from the motor nameplate and is entered in multiples of milliamp. Depending on the motor and drive technology this current may be either DC, peak or rms
Object description:
| Index |
| 6075h |
| Name |
| Motor Rate Current |
| Object code |
| VAR |
| Data type |
| UNSIGNED32 |
| Category |
| Mandatory |
Entry description: |
|
| |
|
|
|
|
| Access |
| Read/write |
| PDO mapping |
| No |
| Value range |
| UNSIGNED32 |
| Default value |
| 0 |
Note: This value of 6075h is set to CL[1] after it is converted to Amperes.
Object 0x6076: Motor Rate Torque
This value is taken from the motor name plate and is entered as a multiple of mNm (mill wtonmeter). All relative torque data refer to this value.
For linear motors, the object name is not changed, but the motor rated force value must be entered as a multiple of mN (mill Newton)..
Object description:
| Index |
| 6076h |
| Name |
| Motor Rate Torque |
| Object code |
| VAR |
| Data type |
| UNSIGNED32 |
| Category |
| Mandatory |
Entry description: |
|
| |
|
|
|
|
| Access |
| Read/write |
| PDO mapping |
| No |
| Value range |
| UNSIGNED32 |
| Default value |
| 0 |