CANopen DSP 402 Implementation Guide
9
3: Emergencies
Emergency messages are detailed in the SimplIQ CANopen Implementation Guide.
4: Predefinition
Object 0x1000: Device type
The object at index 1000h describes the device type and functionality. The SimplIQ returns 0x20192 for servo drive supporting DSP 402.
Object 0x1001: Error register
All bits are defined as in the SimplIQ CANopen Implementation Manual and CiA
The error register captures the latest emergency messages. SimplIQ servo drives allow the user to block the transmission of an emergency according to object 0x2F20. Nevertheless, a blocked emergency message is captured in the relevant entry of the error register.
PDO Mapping
The Elmo drive supports more than one operating mode of DSP 402. It also allows more than one method to set and query commands. In addition, the use of more than one standard PDO is predefined. With the Harmonica, four TPDOs and four RPDOs are free for any mapping according to the Elmo object dictionary. At reset (power up, NMT communication reset and NMT node reset), a default mapping is introduced according to DSP 402. These default mapping can be later changed by the user.
Receive PDO 1 mapped to the controlword in the following manner:
Index |
| Name |
1400h | 0 | Number of entries |
| 1 | |
| 2 | Transmission type |
Default Value
2
4000027Fh
255
Index | Name | Default Value | |
1600h | 0 | Number of mapped entries | 1 |
| 1 | Controlword | 6040 00 10h |