CANopen DSP 402 Implementation Guide
12
5:Common Entries
5.1Drive Error
The drive functionality in case of an error is determined using the following objects:
6007h: defined according to the SimplIQ CANopen Implementation Manual.
603Fh: reflects the 16 lower bits of object 0x1003, which, together with this object, get the emergency value regardless of the emergency message mask in object 2F21h.
Object 0x6007: Abort connection option code
This object details the motor control behavior after a heartbeat failure. It has no effect if the motor is already off.
Object description:
| Index | 6007h |
| Name | Abort connection option code |
| Object code | VAR |
| Data type | INTEGER16 |
| Category | Optional |
Entry description: |
| |
| Access | Read/Write |
| PDO mapping | No |
| Value range | |
| Default value | 0 |
Data description:
(Command details are found in SimplIQ Command Reference Manual.)
Option |
|
|
Code | Meaning | Details |
0 | No action |
|
1 | Malfunction | Motor is off (MO=0) and motor failure code is |
|
| 0x800. The failure is reported and possibly |
|
| activates an AUTOERR routine similar to |
|
| other failures (MF command). |
2 | Device control | Motor is off (MO=0), but no failure indication |
| command | is set (MF=0). |
| “Disable_voltage” |
|
3 | Device control | ST command is executed. Its action depends |
| command “Quick_stop” | on unit mode (UM). |