CANopen DSP 402 Implementation Guide
34
Object 0x605D: Halt option code
This parameter determines which action should be taken if bit 8 (halt) in the controlword is active.
Object description:
| Index |
| 605Dh |
| Name |
| Halt option code |
| Object code |
| VAR |
| Data type |
| INTEGER16 |
| Category |
| Optional |
Entry description: |
|
| |
|
|
|
|
| Access |
| Read/write |
| PDO mapping |
| No |
| Value range |
| INTEGER16 |
| Default value |
| 1 |
Data description: |
|
|
Value | Description |
Manufacturer specific | |
0 | Disable drive function |
1 | Slow down on |
2 | Slow down on |
3 | Slow down on current limit (only for tq mode) |
3…32,767 | Reserved |
In Profile Position mode, the Halt option is not affected when this object is set.