CANopen DSP 402 Implementation Guide
Entry description:
| Access |
| Read only | |
| PDO mapping | Yes | ||
| Value range | UNSIGNED16 | ||
| Default value | No | ||
Data description: |
|
| ||
|
|
|
| |
| Bit | Description |
| |
| 0 | Ready to switch on |
| |
| 1 | Switched on |
| |
| 2 | Operation enabled |
| |
| 3 | Fault |
|
|
| 4 | Voltage enabled |
| |
| 5 | Quick stop |
| |
| 6 | Switch on disabled |
| |
| 7 | Warning |
| |
| 8 | Manufacturer specific |
| |
| 9 | Remote |
| |
| 10 | Target reached |
| |
| 11 | Internal limit active |
| |
| 12 - 13 | Operation mode specific |
| |
| 14 - 15 | Manufacturer specific |
|
Bits 0 - 3, 5 and 6:
The following bits indicate the status of the device:
Value (binary) | State |
xxxx xxxx x0xx 0000 | Not ready to switch on |
xxxx xxxx x1xx 0000 | Switch on disabled |
xxxx xxxx x01x 0001 | Ready to switch on |
xxxx xxxx x01x 0011 | Switch on |
xxxx xxxx x01x 0111 | Operation enabled |
xxxx xxxx x00x 0111 | Quick stop active |
xxxx xxxx x0xx 1111 | Fault reaction active |
xxxx xxxx x0xx 1000 | Fault |
29