CANopen DSP 402 Implementation Guide
32
Data description:
Value | Description |
Manufacturer specific | |
0 | Disable drive function |
1 | Slow down on |
2 | Slow down on |
3 | Slow down on current limit and than disable the drive (tq |
| mode only) |
4 | Not supported |
5 | Slow down on |
7 | Slow down on the current limit and stay in QUICK STOP |
| (tq mode only) |
8 | Not supported |
9…32,767 | Reserved |
An attempt to set an unsupported value causes the transmission of abort code 0609 0030: Value exceeded.
Object 0x605B: Shutdown option code
This parameter determines which action should be taken in case of the transition:
OPERATION ENABLE => READY TO SWITCH ON.
Object description:
| Index |
| 605Bh |
| Name |
| Shutdown option code |
| Object code |
| VAR |
| Data type |
| INTEGER16 |
| Category |
| Optional |
Entry description: |
|
| |
|
|
|
|
| Access |
| Read/write |
| PDO mapping |
| No |
| Value range |
| INTEGER16 |
| Default value |
| 0 |