CANopen DSP 402 Implementation Guide
16
Object 0x6407: Motor service periods
Value, in hours, of the nominal motor lifetime. The motor needs servicing after this time. Object description:
| Index |
| 6407h |
| Name |
| Motor service period |
| Object code |
| VAR |
| Data type |
| UNSIGNED32 |
| Category |
| Optional |
Entry description: |
|
| |
|
|
|
|
| Access |
| Read/Write |
| PDO mapping |
| No |
| Value range |
| Unsigned32 |
| Default value |
| No |
5.3Drive Data
Objects 6500h to 65FFh serve as a database for drive parameters. The Elmo DSP 402 implementation supports the following objects:
6502h: Supported drive modes:
Homing mode (hm), profiled position mode (pp), interpolated position mode (ip), profiled velocity mode (pv), Profiled torque mode (tq).
6504h: Drive manufacturer
6505h: Http drive catalog address
60FDh: Drive digital input
These objects, except 6503h, are “read only” and are burnt into the drive as part of the manufacturing process. Object 6503h is a
HAR A15/200CAN). The default value is 0.
The following objects provide more information about the drive: