B. Facing Material
•Metal front faces may be covered with
•Facing and/or finishing materials must not interfere with air flow through louvers, operation of louvers or doors, or access for service.
•Facing and/or finishing materials must never overhang into the glass opening.
•Observe all clearances when applying combustible materials.
•Seal joints between the finished wall and appliance top and sides using a 300°F minimum sealant. Refer to Figure 14.3.
WARNING! Risk of Fire! DO NOT apply combustible ma- terials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping materials could ignite and will inter- fere with proper operation of doors and louvers.
DO NOT REMOVE!
May be covered with
Finish wall material may be combustible on sides and up to
0 in.
0 in. | 0 in. |
High Temperature Sealant (300° F/149° C min.)
Top and Side Seal Joint
Figure 14.3 Non-combustible Facing Diagram