Vent supports |
|
are per vent | Metal |
manufacturer’s | |
specifications. | Plumbers' |
| Strap |
Maximum horizontal run is 50% of | |
vertical. Horizontal run cannot be | |
more than 20 ft. (6.1 m). | |
Figure 5.2 Maximum Horizontal Run |
|
WARNING
Fire Risk
Explosion Risk
Insulation and other combustibles must not infringe on clearances.
•ALWAYS maintain specifi ed clearances around venting and fi restop systems.
•Install fi restops as specifi ed.
Failure to keep insulation or other material away from vent pipe may cause fi re.
Maximum horizontal 20 ft (6.1 m)
45° | Offsets exceeding |
Elbow | |
| 45° adapt horizontal |
90° | limitations |
| |
Elbow |
|
| Note: Maximum horizontal |
| distance is 50% of vertical |
| vent height. |
Note:
fixed glass door. Only
first elbow.
Figure 5.3 Maximum Horizontal Run
14 | Heatilator • GB4336/GB4992 • |