Heatiator GB4336 owner manual D. High Altitude Installations, Fire Risk Explosion Risk

Page 20
•Gas build-up during line purge may ignite.

A small amount of air will be in the gas supply lines. When fi rst lighting appliance it will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally.

Manual background WARNING

Fire Risk

Explosion Risk

Gas build-up during line purge may ignite.

Purge should be performed by qualifi ed technician.

Ensure adequate ventilation.

Ensure there are no ignition sources such as sparks or open fl ames.

D. High Altitude Installations

U.L. listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 ft in the USA and Canada.

When installing this appliance at an elevation above 2000 ft, it may be necessary to decrease the input rating by chang- ing the existing burner orifi ce to a smaller size. Input rate should be reduced by 4% for each 1000 ft above a 2000 ft elevation in the U.S.A., or 10% for elevations between 2000 and 4500 ft in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the prop- er orifi ce size, check with the local gas utility.

If installing this appliance at an elevation above 4500 ft (in Canada), check with local authorities.

Manual background WARNING

CHECK FOR GAS LEAKS

Fire Risk

Explosion Risk

Asphyxiation Risk

Check all fi ttings and connections.

Do not use open fl ame.

After the gas line installation is complete, all connections must be tightened and checked for leaks with a commercially available, non-corrosive leak check solution. Be sure to rinse off all leak check solution following testing.

Fittings and connections may have loosened during shipping and handling.

Manual background WARNING

Fire Risk

Explosion Risk

Do NOT change the valve settings.

This valve has been preset at the factory.

Changing valve settings may result in fire hazard or bodily injury.

20

Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06

Image 20
Contents What to do if you smell gas Models GB4336, GB4336L GB4336I, GB4336ILGB4942, GB4942L GB4942I, GB4942IL B-VentGas ApplianceHomeowner Reference Information Listing Label Information/LocationCongratulations Gas TypeTable of Contents 5 Vent Information and Diagrams8 Installing Vent Pipe 12 Appliance SetupD. High Altitude Installations 1Listing and Code ApprovalsA. Appliance Certification C. BTU SpecificationsA. Design and Installation Considerations 2Getting StartedAsphyxiation Risk B. Negative PressureNegative Pressure Any such action may cause a fire hazard C. Tools and Supplies NeededD. Inspect the Appliance and Components Fire Risk 3Framing and ClearancesA. Select Appliance Location B. Construct the Appliance Chase Fire RiskC. Clearances Fire Risk Odor RiskD. Mantel Projections Top of Appliance Drywall A 48 in 1219 mm B maxMantel Leg or Perpendicular Wall A1 in. 25mm min to perpendicular wallFire Risk Explosion Risk 4Termination LocationsA. Vent Termination Minimum Clearances 5Vent Information and Diagrams A. Vent GuidelinesB. Vent System Configuration Fire Risk Asphyxiation RiskVent supports Fire Risk Explosion Risk6Vent Clearances and Framing A. Pipe Clearances to CombustiblesB. Wall Penetration Framing C. Vertical Penetration FramingA. Installing Outside Air Kit Damper Assembly Appliance PreparationRisk of Smoke Spillage Fire Risk Asphyxiation RiskB. Gas and Electrical Connections C. Securing and Leveling ApplianceNailing Tabs both sides8Installing Vent Pipe B. Attach Vent to Firebox AssemblyA. Assemble Vent Sections C. Securing Vent Sections9Gas Information A. Fuel ConversionC. Gas Connection B. Gas PressureD. High Altitude Installations Fire Risk Explosion RiskGas build-upduring line purge may ignite Fire Risk Explosion Risk Asphyxiation RiskA. Recommendation for Wire B. Connecting to the ApplianceC. Intellifire Ignition System Wiring 10 Electrical InformationOptional Junction Box Wiring D. Standing Pilot Ignition System WiringOptional Accessories Requirements E. Junction Box Installation 11 Finishing A. Mantel ProjectionsB. Facing Material Fire Risk12 Appliance Setup B. Clean the ApplianceC. Accessories D.Install the RefractoryF. Log Removal/Replacement I. Air Shutter Setting G. Glass DoorsH. Hood Fire Risk Combustion Fumes Risk13 Operating Instructions A. Before Lighting ApplianceFire Risk Burn Risk HOT! DO NOT TOUCH SEVERE BURNS MAY RESULTC. High Limit Safety Switch B. Check Appliance DraftNote to Qualified Service Technician WithoutD. Lighting the Appliance WARNING RISK OF FIREFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONSFOR YOUR SAFETY READ BEFORE LIGHTING NATURAL GASLIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCEF. Frequently Asked Questions E. After the Appliance is LitInitial Break-inProcedure Issue14 Troubleshooting A. Standing Pilot Ignition SystemSymptom Possible CausesSymptom Possible CausesCorrective Actions Frequent pilot outageB. Intellifire Ignition System SymptomPossible Causes Corrective ActionsSymptom Possible CausesCorrective Actions Pilot sparks, but pilot will15 Maintaining and Servicing the Appliance CleanWhen cleaning glass door Risk of injury or property damageMaintenance and Service Tasks Maintenance TasksInspect one is not presentA. Appliance Dimension Diagram 16 Reference MaterialsFigure 16.1 Appliance Dimensions ModelService Parts B. Service Parts ListGB4336 SERIES Exploded Parts DiagramService Parts GB4336 SERIESDescription of Part GB4336Standing Pilot Valve Assembly Intermittent Pilot Valve AssemblyService Parts Service Parts ListService Parts GB4336 SERIESDescription of Part GB4336GB4942 SERIES Service PartsExploded Parts Diagram Beginning Manufacturing Date 1/19/04Service Parts GB4942 SERIES# Description of Part GB4942Service Parts Standing Pilot Valve AssemblyIntermittent Pilot Valve Assembly Service Parts ListService Parts GB4942 SERIES# Description of Part GB4942C. Optional Components ID4 Insulated Ductin. 102 mm UD4 Uninsulated Duct 4 in. 102 mm 42 in 1067 mmThis page intentionally left blank This page intentionally left blank D. Limited Lifetime Warranty Gas Appliance Fireplace Limited Lifetime WarrantyLimited Lifetime Warranty 1 Year Limited WarrantyE. Contact Information Hearth & Home Technologies Inc1915 W. Saunders Street Mt. Pleasant, Iowa DO NOT DISCARD THIS MANUAL