IROB Protectors

Equipment that is connected to the analog station jacks

 

(408/008) and is located in a building outside of the main

 

(control unit location) building, but within 1000 feet of the

 

control unit, is called In-Range, Out-of-Building (IROB)

 

equipment. To protect both the control unit and the IROB

 

equipment from exposure to lightning, in advertent contact

 

with power lines, and power currents induced by nearby

 

power lines, IROB protectors are required. Two TII

 

Model 343 IROB Protectors are required for every analog

 

station jack that is connected to IROB equipment. Place

 

one IROB protector where the cable from the control unit

 

leaves the building, and place the other where the cable

 

enters the building in which the IROB equipment is

 

located (Figure 2-35).Refer to the installation notes that

 

are packed with the IROB Protector for detailed

 

instructions on proper installation. See “System

 

Grounding Requirements” on page 2-5 for more

 

information on grounding.

 

.

 

 

 

WARNING: Only analog station-modules (408, 008) are

 

to be used for In-Range, Out-of-Building (IROB)

 

applications. The Digital Station Modules (008D) and

 

the Basic Telephone Modules (012) cannot be used for

 

IROB applications.

 

 

2-126 Adding Accessories

Page 194
Image 194
AT&T 518-600-016 Equipment that is connected to the analog station jacks, Are packed with the Irob Protector for detailed