SYSTEM CAPACITY The MERLIN II system hardware limits the system capacity for the items found in Table 1-2.

TABLE 1-2 MERLIN II System Capacity

Item

Capacity

 

 

Module slots

17

 

 

Board signatures

16

 

 

Time slots -

256

 

 

Simultaneous duplex connections

108

 

 

Tones

40

 

 

Table 1-3 lists items that the system architecture either allows or requires.

TABLE 1-3 Port Requirements for Features and System

Accessories

Feature

 

Port Requirements

 

 

 

 

 

 

Music-on-Hold interface

1 CO line (administered)

 

 

 

 

 

External paging interface

1

CO line (administered)

 

 

 

 

Analog Simultaneous Voice/Data

2 ATL station ports

 

 

 

 

 

Analog Voice Announcement

 

 

 

to Busy Voice Terminal

2 ATL station ports

 

 

 

 

 

Digital Simultaneous Voice/Data

1

DCP station port

 

 

 

 

Extra alert devices (with SAA)

1 ATL station port

 

 

 

 

 