●Green
●Outside line numbering strips. These labels are used
to number all the line jacks on the modules themselves.
You can have up to 56 outside line jacks with the MERLIN II system. The numbering sequence is 01 to 56. To connect the outside line wiring, follow these steps:
1 Review Form 1a, System
The outside line numbers are the telephone numbers listed at the network interface or inside the left door of the box in the jack field containing the jacks for your outside lines.
2 Number sequentially from 01 to 56 every outside line jack on the modules using the outside line numbering strips. Begin with the module in slot 1, numbering from bottom to top and working from left to right across the control unit (See Figure
Refer to Figure
3 Connect the outside line jacks on the modules to the network interface using D2R cords. Thread the wires through the wire managers at the base of each module as you connect the wires to the jacks. Label each end of each cord with the outside line jack number to which each is connected.