Frequency range. 60 Hz +/- 1 percent

 

Max. current. 3 amperes per power supply

 

Max. power use. 225 watts per power supply

GROUNDING

The system must be connected to a properly grounded ac

REQUIREMENTS

outlet. See page 2-5, “System Grounding Requirements,”

 

for more information.

 

NOTE: If Modular Processor Data Modules, Modular

 

 

 

Trunk Data Modules, or moderns are to be

 

 

 

installed at the control unit location, additional

 

 

 

grounded ac outlets will be needed.

WIRE LENGTH

Wires connected to the control unit should consist of a

LIMITATIONS

single continuous run, i.e., without extension cords or

 

other splices, and should meet these specifications:

 

 

 

Power cord. The power cord must be less than 6 feet,

 

 

 

and must be connected to a properly grounded ac

 

 

 

outlet that is not switch-controlled.

 

 

 

Incoming lines. The distance from the network

 

 

 

interface provided by the local telephone company for

 

 

 

incoming lines must be spanned within one cord length

 

 

 

(generally 25 feet or less).

 

 

 

Jack field. The distance to the jack field mounted to

 

 

 

the left of the earner must be

 

 

 

Station. Each voice terminal must be within 1000 feet

 

 

 

of the control unit.

 

 

 

 

 

 

 

WARNING: If a voice terminal is used for In-Range,

 

 

 

Out-of-Building (IROB) applications, IROB

 

 

 

protectors are required. See “IROB Protectors” on

 

 

 

page 2-126 for more information.

 

 

 

 