SPACE AND

LOCATION REQUIRIEMENTS

WARNING: The control unit cannot be installed outdoors. It must be installed in an environment suitable for electronic equipment. Do not expose the control unit to devices that generate electrical interference such as arc welders or motors.

The control unit should be located with the following points in mind:

CO line protection. The control unit should be installed near the Central Office line protectors

provided by the local telephone company. Refer to “System Grounding Requirements” on page 2-5 for additional information about line protection.

Ventilation. Allow at least 1 inch of space on the right and left sides of the control unit and 12 inches of space above and below the control unit to prevent overheating. Do not place the control unit near extreme heat or in direct sunlight.

Placement. AIlow at least 1 foot of space to the right of the basic carrier for expansion and at least two feet of space to the left for a jack field. Refer to “Wiring the System” on page 2-12 and “Jack Field Wiring” on page 2-33 for additional information on space requirements.

POWER

Listed below are the power requirements and

REQUIREMENTS

specifications for the control unit:

SPECIFICATIONS

Voltage range. 99 to 129 VAC

 

 

Voltages generated by the power supply remain within

 

specification for an ac line voltage low of 99 VAC.

 

The system will bridge a 40 millisecond supply outage

 

without dc voltages being affected.

2-2 Preinstallation Requirements

Page 70
Image 70
AT&T 518-600-016 manual Specification for an ac line voltage low of 99 VAC, Without dc voltages being affected