Each module has a DSE to interface codecs or digital transceivers to the TDM bus. The actual digital switching occurs when the DSE is programmed by the system I/O bus to place (transmit) data or retrieve (receive) data on the TDM bus in specific time slots. This process also involves time slot interchanging so that an available slot in the TDM cycle can be filled with a talk (transmit) or listen (receive) slot. The DSE provides dynamic conferencing ability by allowing up to 16 time slots to be conference together and sent out to a single port (station).

DSE

408 Module

CODEC

D / A converter

A / D

converter

i n t e r f a c e

Analog voice terminal

DSE

008D Module

Interface circuity

TDM Bus

256 Time slots in one TDM cycle

0

1

2

3

60 61 62 63

150

160

200

220

225

Time

Time slots

Time slots

Analog station

Digital station

for control

for tones.

talks on time

sends data on

signals.

 

slot 150 and

time slot 200

 

 

listens on time

and receives

 

 

slot 160. The

data on time

 

 

conversation

slot 220.

 

 

is continuous.

 

FIGURE 1-10 Time division multiplexing.

Theory of Operation 1-43