Possible Cause

 

Possible Solution

 

To Investigate Further

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Faulty cable connection.

 

Step 1. Go to the control

 

If the trouble still occurs, the

 

 

 

 

 

 

 

unit and locate the intercom

 

 

 

 

 

trouble is in the control unit.

 

 

 

jacks for the malfunctioning

 

 

 

 

 

Call the equipment supplier

 

 

 

voice terminal and for a

 

 

 

 

 

for assistance.

 

 

 

working voice terminal of

 

 

 

 

 

 

 

 

 

the same type (analog or

 

 

 

 

 

digital). Unplug both from

 

 

 

 

 

the control unit and replug

 

 

 

 

 

the working voice terminal

 

 

 

 

 

into the malfunctioning

 

 

 

 

 

voice terminal jack. See if

 

 

 

 

 

the trouble occurs on the

 

 

 

 

 

working voice terminal.

 

 

 

 

 

If the trouble no longer

 

Go to Step 2.

 

 

 

occurs, the trouble is caused

 

 

 

 

 

 

 

 

 

by one of the cables running

 

 

 

 

 

to the malfunctioning voice

 

 

 

 

 

terminal.

 

 

 

 

 

 

 

 

 

 

 

Step 2. Replace each cable

 

 

 

 

 

of the wiring run to the

 

 

 

 

 

malfunctioning voice

 

 

 

 

 

terminal one at a time, and

 

 

 

 

 

test the malfunctioninig voice

 

 

 

 

 

terminal after each cable is

 

 

 

 

 

replaced. If the trouble still

 

 

 

 

 

occurs the replaced cable is

 

 

 

 

 

not the faulty one. Replace

 

 

 

 

 

the next cable.

 

 

 

 

 

If the trouble no longer

 

 

 

 

 

occurs, you’ve found the

 

 

 

 

 

faulty cable and corrected

 

 

 

 

 

the problem.

 

 

 

 

 

 

 

 