CHANGED

INTERCOM NUMBERS OR FEATURES

Symptom: Intercom numbers have changed or features assigned to a person's station have changed.

Either of these conditions can occur when a system has been readministered and the wires to the stations affected have not been connected to the jacks that reflect the latest administration.

Possible Cause

Possible Solution

To Investigate Further

 

 

 

1 The station is not

Check that station wiring is

 

connected to the correct jack.

connected to the correct jack.

 

 

If the connections are

 

 

incorrect plug the wires into

 

 

the jacks as intended by the

 

 

current administration.

 

 

If the connections are

 

 

correct, check the positions

 

 

and numbering of the

 

 

modules on the carrier. If the

 

 

modules are not placed in the

 

 

correct order or the intercom

 

 

numbers do not reflect

 

 

current administration, turn

 

 

the power off, place the

 

 

modules in their correct

 

 

order, and renumber the

 

 

intercom numbers to reflect

 

 

current administration.

 

 

Check your administration

 

 

forms and readminister the

 

 

affected stations.

 

 

If modules are in their

If the planning forms are

 

correct positions, numbered

correct go to "General Tests"

 

appropriately, and connected

on page 4-55 before calling

 

to the correct stations, verify

the equipment supplier.

 

your planning forms.

 

Procedures for Specific Symptoms 4-51

Page 382
Image 382
AT&T 518-600-016 manual Changed