AT&T 518-600-016 manual Installing the Control Unit

Models: 518-600-016

1 404
Download 404 pages 54.08 Kb
Page 155
Image 155

1Locate the Z200A EMI filter. Notice that the filter is closer to one end of the cord than the other. Plug the end of the cord closest to the filter into the SMDR port of the Processor Module. The SMDR port is the top port on the Processor Module.

2Plug the other end of the EMI filter into the modular jack on the adapter (355AF or 355A).

3Connect the female connector on the 355AF adapter to one end of the EIA crossover cable. Connect the other end of the cable to the 25-pin male connector of the Z3AI ADU.

4Connect the modular jack marked “telephone” on the ADU to one of the input modular jacks on the 400B2 power adapter. The 2012D ac transformer is connected to the other input modular jack of the power adapter via a 248B adapter and a D6AP-87 power cord.

5Plug the output modular jack from the 400B2 adapter into the ADU crossover cable (D8AM-87). Connect the output of the D8AM-87 to the building wiring.

WARNING: If the printer is in a building outside of the main (control unit location) building, an ADU and an additional protector must be installed in each building. The ADUs and protectors provide both the control unit and the printer additional protection against exposure to lightning, inadvertent contact with power lines, and power currents induced by nearby power lines. See the ADU installation notes for more information.

Installing the Control Unit 2-87

Page 155
Image 155
AT&T 518-600-016 manual Installing the Control Unit