Desa CCL3018PT Installing Damper Clamp Accessory for Vented Operation, Installation Items Needed

Page 10

10

INSTALLATION

Installing Damper Clamp Accessory for Vented Operation Installing Heater Base Assembly

INSTALLATION

Continued

INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION

Note: When used as a vented heater, appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material.

If your heater is a manually controlled model, you may use this heater as a vented product. There are three reasons for operating your heater in the vented mode.

1.The fireplace does not meet the clearance to combustibles re- quirements for vent-free operation.

2.State or local codes do not permit vent-free operation.

3.You prefer vented operation.

If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 28). This will insure vented operation (see Figure 11). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

Chimney

Minimum Permanent

Height (ft.)

Flue Opening (sq. ins.)

 

 

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

 

 

Area of Various Standard

Round Flues

Diameter (ins.)

Area (sq. ins.)

 

 

5"

20 sq. inches

6"

29 sq. inches

7"

39 sq. inches

8"

51 sq. inches

 

 

Damper Clamp

Damper Clamp

Damper

Damper

Damper

 

 

Masonry Fireplace

Manufactured Fireplace

Figure 11 - Attaching Damper Clamp

INSTALLING HEATER BASE ASSEMBLY

CAUTION: Do not remove the data plates attached to the heater base assembly. The data plates contain important warranty and safety information.

WARNING: You must secure this heater to fire- place floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.

WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fireplace floor to allow access to heater control panel. This will insure adequate air flow and guard against sooting and con- trols being damaged. Raise fireplace floor with non- combustible material. Make sure material is secure.

CAUTION: Do not pick up heater base assembly by the burner. This could damage heater. Only handle base assembly by grates.

IMPORTANT: Make sure the heater burners are level. If heater is not level, heater will not work properly. For thermostat models, avoid damage to thermostat bulb. Avoid nicks or sharp bends in thermostat bulb wire. Keep thermostat bulb in mounting bracket until ready to mount base to floor. See Optional Positioning Of Thermostat Sensing Bulb, page 27.

Installation Items Needed

hardware package (provided with heater)

approved flexible gas hose (not provided) (if allowed by local codes)

sealant resistant to propane (propane/LP) gas, not provided

electric drill with 3/16" drill bit

flathead screwdriver

1.Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulator. Connect approved flexible gas hose to gas regulator of heater (see Figure 12).

IMPORTANT: Hold gas regulator with wrench when connecting flexible gas hose.

2.Locate masonry screws in hardware package.

3.Position heater base assembly in fireplace.

4.Place logs in their proper position on heater base, see Installing Logs on pages 13 through 18.

5.Center heater base and logs front-to-back and side-to-side in fireplace.

6.Carefully remove logs without moving heater base.

For..com

107124-01E

Image 10
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Local Codes Product Features AIR for Combustion and VentilationUnpacking Confined and Unconfined Space Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Uncon- fined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Check GAS TypeIf Using Mantel Minimum Noncombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Connecting to GAS Supply Attaching Flexible Gas Hose to Heater Gas RegulatorPressure Testing Gas Supply Piping system Checking GAS ConnectionsPressure Testing Heater Gas Connections Installing LogsDual Burner Smoky Mountain Oak Models Installing Middle Log #2 Dual Burner Premium Aged Split Oak ModelsInstalling Front Log #4 Installing Middle Log #2 CCL3930PTA Shown Dual Burner Biltmore Split Oak ModelsInstalling Crossover Log #5 CCL3930PTA Shown Installing Front Log Single Burner Seasonal Oak ModelsOperating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS to Appliance Manual Lighting ProcedureVariable Control Operation Shutting Off HeaterElectrode Thermocouple Pilot Flame Pattern Inspecting BurnersThermostat Control Operation Burner Primary AIR HolesCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Troubleshooting Observed Problem Possible Cause RemedyFor more Visit www Com Gas leak. See Warning statement Optional Positioning of Thermostat Sensing Bulb For Masonry and Factory-built Metal FireplaceService Hints Replacement PartsAccessories Technical ServiceDual Burner Biltmore Split OAK Models SpecificationsSingle Burner Seasonal OAK Models Illustrated Parts Breakdown Variable Manually-ControlledParts List CGD3930P, CCL3018P CCL3924PCGD3018PT CGD3924PT CGD3930PT Thermostatically-Controlled Smoky Mountain Oak ModelsCGD3924PT and CGD3930PT CCL3018PT Thermostatically-Controlled Biltmore Split Oak ModelKEY Part Number CCL3018PT Description QTY CCL3924PT CCL3930PTA Thermostatically-Controlled Biltmore Split Oak ModelVariable Manually-Controlled Seasonal Oak Models Seasonal Oak Models Description QTYParts Central Owners Registration Form Postage Required 107124-01E Warranty Information Keep this Warranty