Desa CCL3930PTA, CRL2718P, CRL3124P, CCL3018P Specifications, Dual Burner Biltmore Split OAK Models

Page 29

SPECIFICATIONS

29

SPECIFICATIONS

DUAL BURNER SMOKY MOUNTAIN OAK AND PREMIUM AGED

SPLIT OAK MODELS

 

18" Model

24" Models

30" Models

Btu (Variable)

16,000/30,000

20,000/39,000

20,000/39,000

Type Gas

Propane/LP Only

Propane/LP Only

Propane/LP Only

Ignition

Piezo

Piezo

Piezo

Manifold Pressure

8.0" W.C.

8.0" W.C.

8.0" W.C.

Inlet Gas

 

 

 

Pressure (in. of water)

 

 

 

Maximum

14"

14"

14"

Minimum*

11"

11"

11"

Shipping Weight

36 lbs.

38 lbs.

40 lbs.

* For the purpose of input adjustment

DUAL BURNER BILTMORE SPLIT OAK MODELS

 

18" Model

24" Models

30" Models

Btu (Variable)

16,000/30,000

20,000/39,000

20,000/39,000

Type Gas

Propane/LP Only

Propane/LP Only

Propane/LP Only

Ignition

Piezo

Piezo

Piezo

Manifold Pressure

8.0" W.C.

8.0" W.C.

8.0" W.C.

Inlet Gas

 

 

 

Pressure (in. of water)

 

 

 

Maximum

14"

14"

14"

Minimum*

11"

11"

11"

Shipping Weight

61 lbs.

66 lbs.

70 lbs.

* For the purpose of input adjustment

SINGLE BURNER SEASONAL OAK MODELS

 

18" Model

24" Model

Btu (Variable)

16,000/27,500

16,000/31,500

Type Gas

Propane/LP Only

Propane/LP Only

Ignition

Piezo

Piezo

Manifold Pressure

8.0" W.C.

8.0" W.C.

Inlet Gas

 

 

Pressure (in. of water)

 

 

Maximum

14"

14"

Minimum*

11"

11"

Shipping Weight

TBD lbs.

TBD lbs.

* For the purpose of input adjustment

For morevisit www..com

107124-01E

Image 29
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Unpacking Product Features AIR for Combustion and VentilationLocal Codes Determining if You Have a Confined or Uncon- fined Space Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationMinimum Noncombustible Material Clearances If Using MantelMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Attaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping systemDual Burner Smoky Mountain Oak Models Installing LogsPressure Testing Heater Gas Connections Dual Burner Premium Aged Split Oak Models Installing Middle Log #2Installing Front Log #4 Dual Burner Biltmore Split Oak Models Installing Middle Log #2 CCL3930PTA ShownInstalling Crossover Log #5 CCL3930PTA Shown Single Burner Seasonal Oak Models Installing Front LogLighting Instructions For Your Safety Read Before LightingOperating Heater Variable Control Operation Manual Lighting ProcedureTo Turn OFF GAS to Appliance Shutting Off HeaterElectrode Thermocouple Thermostat Control Operation Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesLogs Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Observed Problem Possible Cause Remedy TroubleshootingFor more Visit www Com Gas leak. See Warning statement For Masonry and Factory-built Metal Fireplace Optional Positioning of Thermostat Sensing BulbAccessories Replacement PartsService Hints Technical ServiceSingle Burner Seasonal OAK Models SpecificationsDual Burner Biltmore Split OAK Models Variable Manually-Controlled Illustrated Parts BreakdownCGD3930P, CCL3018P CCL3924P Parts ListThermostatically-Controlled Smoky Mountain Oak Models CGD3018PT CGD3924PT CGD3930PTCGD3924PT and CGD3930PT Thermostatically-Controlled Biltmore Split Oak Model CCL3018PTKEY Part Number CCL3018PT Description QTY CCL3924PT CCL3930PTA Biltmore Split Oak Model Thermostatically-ControlledVariable Manually-Controlled Seasonal Oak Models Description QTY Seasonal Oak ModelsParts Central Owners Registration Form Postage Required 107124-01E Keep this Warranty Warranty Information