Desa CCL3924P, CRL2718P, CRL3124P, CCL3018P, CGD3924P, CGD3018PT Installation, Check GAS Type

Page 7

INSTALLATION

Check Gas Type Installation and Clearances for Vent-Free Operation

7

INSTALLATION

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using log heater. This will help circulate the heat from your log heater throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified service person must in- stall heater. Follow all local codes.

NOTICE: State or local codes may only allow opera- tion of this appliance in a vented configuration. Check your state or local codes.

WARNING: Before installing in a solid fuel burn- ing fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes, and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within house. Inspect chimney flue and firebox for damage. If damaged, operate heater with flue damper closed.

WARNING: Seal any fresh air vents or ash clean- out doors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat- resistant sealant. Do not seal chimney flue damper.

WARNING: Never install the heater

in a bedroom or bathroom unless installed as a vented appliance (Variable Manually-Controlled Models Only) (see page 10)

in a recreational vehicle

where curtains, furniture, clothing, or other flam- mable objects are less than 42 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough venti- lation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 4 through 6.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply is not propane/LP, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION AND CLEARANCES (Vent-Free Operation Only)

WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceil- ing, and adjoining wall.

MINIMUM FIREPLACE CLEARANCE

TO COMBUSTIBLE MATERIALS

Log Size

 

Side Wall

Ceiling

 

 

 

 

 

 

 

18", 24", 30"

 

16"

 

42"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOG SIZING REQUIREMENTS

 

Minimum Firebox Size

 

 

 

 

 

 

Log

 

 

 

Front

Rear*

Size

Height

Depth

Width

Width

18"

17"

14"

24"

 

20"

24"

17"

14"

28"

 

21"

30"

17"

14"

34"

 

24"

 

 

 

 

 

 

 

*Measured at 14" depth

Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127-listed manufactured fireplace, or certified vent-free firebox.

For morevisit www..com

107124-01E

Image 7
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Local Codes Product Features AIR for Combustion and VentilationUnpacking Confined and Unconfined Space Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Uncon- fined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationMinimum Noncombustible Material Clearances If Using MantelDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Attaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping systemPressure Testing Heater Gas Connections Installing LogsDual Burner Smoky Mountain Oak Models Dual Burner Premium Aged Split Oak Models Installing Middle Log #2Installing Front Log #4 Dual Burner Biltmore Split Oak Models Installing Middle Log #2 CCL3930PTA ShownInstalling Crossover Log #5 CCL3930PTA Shown Single Burner Seasonal Oak Models Installing Front LogOperating Heater For Your Safety Read Before LightingLighting Instructions Shutting Off Heater Manual Lighting ProcedureVariable Control Operation To Turn OFF GAS to ApplianceElectrode Thermocouple Burner Primary AIR Holes Inspecting BurnersThermostat Control Operation Pilot Flame PatternCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingFor more Visit www Com Gas leak. See Warning statement For Masonry and Factory-built Metal Fireplace Optional Positioning of Thermostat Sensing BulbTechnical Service Replacement PartsAccessories Service HintsDual Burner Biltmore Split OAK Models SpecificationsSingle Burner Seasonal OAK Models Variable Manually-Controlled Illustrated Parts BreakdownCGD3930P, CCL3018P CCL3924P Parts ListThermostatically-Controlled Smoky Mountain Oak Models CGD3018PT CGD3924PT CGD3930PTCGD3924PT and CGD3930PT Thermostatically-Controlled Biltmore Split Oak Model CCL3018PTKEY Part Number CCL3018PT Description QTY CCL3924PT CCL3930PTA Biltmore Split Oak Model Thermostatically-ControlledVariable Manually-Controlled Seasonal Oak Models Description QTY Seasonal Oak ModelsParts Central Owners Registration Form Postage Required 107124-01E Keep this Warranty Warranty Information