INSTALLATION
Checking Gas Connections (Cont.) Installing Logs
13
INSTALLATION
Continued
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1.Close equipment shutoff valve (see Figure 17).
2.Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve.
3.Check all joints from propane/LP supply tank to equipment shutoff valve (see Figure 18). Apply a noncorrosive leak de- tection fluid to all joints. Bubbles forming show a leak.
4.Correct all leaks at once.
INSTALLING LOGS
CAUTION: After installation and periodically there- after, check to ensure that no flame comes in contact with any log. With the heater set to high, check to see if flames contact any log. If so, reposition logs according to the log installation instructions in this manual. Flames contacting logs will create soot.
Pressure Testing Heater Gas Connections
1. | Open equipment shutoff valve (see Figure 17). |
2. | Open propane/LP supply tank valve. |
3. | Make sure control knob of heater is in the OFF position. |
4. | Check all joints from equipment shutoff valve to control valve |
| (see Figure 18). Apply a noncorrosive leak detection fluid to |
| all joints. Bubbles forming show a leak. |
5. | Correct all leaks at once. |
6. | Light heater (see Operating Heater, pages 19 and 20 [manu- |
| |
| controlled models]). Check all other internal joints for leaks. |
7. | Turn off heater (see To Turn Off Gas to Appliance, page 20 |
|
Dual Burner Smoky Mountain Oak Models
WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.
1.Locate pins on the bottom of back log (#1). Slide these pins into the holes in the grate base behind the burner (see Figure 19).
trolled models]). |
Open
Pin
Back Log (#1)
Equipment
Shutoff
Valve
Closed
Figure 17 - Equipment Shutoff Valve
Hole in Grate Base
Propane/LP Supply Tank
Equipment |
Shutoff Valve |
Thermostat Gas Valve or |
Control Valve Location |
Burner
Figure 19 - Installing Back Log (#1)
Figure 18 - Checking Gas Joints
For morevisit www..com