Quadra-Fire CB1200-B CB 1200 Pellet Stove, Behind left side curtain on outside of hopper wall

Page 2

CB 1200 Pellet Stove

R

and Welcome to the Quadra-Fire Family!

Hearth & Home Technologies welcomes you to our tradi- tion of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durabil- ity, and performance.

This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum operation

of our stoves, inserts and fireplaces. And yet we are old- fashioned when it comes to craftsmanship. Each unit is meticulously fabricated and surfaces are hand-finished for lasting beauty and enjoyment. Our pledge to quality is com- pleted as each model undergoes a quality control inspec- tion. From design, to fabrication, to shipping:

We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing Quadra-Fire.

SAMPLE SERIAL NUMBER / SAFETY LABEL LOCATION:

Behind left side curtain on outside of hopper wall.

CAUTION: HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. Operate this unit with fuel hopper lid closed. Failure to do so may result in emissions products' combustion from the hopper under certain conditions. Maintain hopper seal in good condition. Do no over fill the hopper.

ATTENTION: CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS. Opérez cet appareil avec le couvercle de la trémie fermé. Le défaut de ne pas suivre les instructions peut résulter, sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine.

Testing Lab & Report Number

Listed by

 

O-T L

Oregon USA

Report / Rapport

Tested and

 

Portland

 

 

C

 

US

061-S-21-4

OMNI-Test Laboratories, Inc.

Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home Installation. This appliance has been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 814-23-909.

Tested to: ASTM E1509-95, ULC/ORD-C-1482-M1990, ULC S627-M93 Room Heating Pellet Burning Type,

APFI, (UM) 84-HUD FOR USE ONLY WITH PELLETIZED WOOD OR SHELLED FIELD CORN FUEL. Input Rating: 40,000 Btu's/hr

Electrical Rating: 115 VAC, 60 Hz, Start 4.6 Amps, Run 1.6 AMPS.

Route power cord away from unit. Do not route cord under or in front of appliance.

DANGER: Risk of electrical shock. Disconnect power supply before servicing. Replace glass only with 5mm ceramic available from your dealer. To start, set thermostat above room temperature, the stove will light automatically. To shutdown, set thermostat to below room temperature. For further instruction refer to owner's manual.Keep viewing and ash removal doors tightly closed during operation.

SERIAL NO. / NUMÉRO DU

CB 1200 Pellet Stove 007C

Appareil de chauffage inséré de combustible solide/de type de boulettes. Accepté dans l'installation dans les maisons mobiles. Cet appareil a été testé et enregistré pour l'usage dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909.

Testé à: ASTM E1509-95, ULC/ORD-C 1482-M1990, ULC S627-M93 Room Heating. Pellet Burning Type, APFI, (UM)

84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS OU DE COMBUSTIBLE DE MAIS ÉCOSSÉ DES CHAMPS. Puissance de Rendement: 40,000 Btu's/hr

Puissance Électrique: 115 VAC, 60 Hz, Début 4.6 Amps, Courir 1.6 Amps,

Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil. DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact avant le service. Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur.

Pour allumer, monter la température du thermostat au dessus de la température de la pièce, le poêle s'allumera automatiquement. Pour éteindre, descendre la température du thermostat en dessous de la température de la pièce. Pour des instructions supplémentaires, référez vous au manuel du propriétaire. Gardez la porte d'ouverture et la porte des cendres fermées hermétiquement durant l'opération.

Serial Number

Model

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS / ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:

A

C

D

C

 

B

 

C

B

 

 

 

Note 1: In residential installations, when using Parts 811-0580, (3" - 3" Top Vent Adapter) and 812-2690 (3" - 6" Top Vent Adapter Collar) 24 gauge 6" single wall flue connector may be used.

Note 1: Dans les installations résidentielles, lorsque les pièces 811-0580, (dessus de l'adapteur de ventilation 3" - 3") et 812-2690 (collier de l'adapteur de ventilation 3" - 6"), un tuyau connecteur de 6" pour mur simple de calibre 24 peut être utilisé.

Note 2: In manufactured home installation, when using Part 811-0580, (3" - 3" Top Vent Adapter) and 812-2690 (3' - 6" Top Vent Adapter Collar), use listed double wall flue connector. An Outside Air Kit (Part 811-0560 rear or 811-0570 floor), must be used with manufactured home installation.

Note 2: Pour l'installation dans les maisons préfabriquées, lorsque les pièces 811-0580 (dessus de l'adapteur de ventilation 3" - 3") et 812-2690 (collier de l'adapteur de ventilation 3" - 6"), utilisez un tuyau connecteur enregistré pour mur double. Un assemblage d'air extérieur (pièce 811-0560 arrière au 811-0570 la plancer), doit être utilisé pour l'installation dans les maisons préfabriquées.

 

 

 

C

 

Back Wall to stove / Mur Arrière du poêle

2"/51mm

 

 

 

B

Side Wall to Cast Top / Mur De Côté du haut

6"/152mm

 

 

 

 

 

 

CORNER INSTALLATION / NSTALLATION DU COIN :

 

 

 

B

C

Side Wall / Mur De Côté

2"/51mm

 

 

 

 

 

 

VERTICAL ADAPTER KIT INSTALLATION:

 

 

 

 

 

 

 

UN ASSEMBLAGE POUR ADAPTEUR POUR INSTALLATION VERTICALE:

 

 

 

 

 

 

 

D

Back Wall to Flue Pipe / Mur Arrière tuyau rigide

3"/76mm

F

 

 

 

 

B

Side Wall to Cast Top / Mur De Côté du haut

6"/152mm

 

D

CORNER INSTALLATION WITH VERTICAL ADAPTER KIT:

 

 

 

 

INSTALLATION DU COIN AVEC UN ASSEMBLAGE D'ADAPTEUR VERTICAL:

 

 

 

 

 

 

 

 

Side Wall / Mur De Côté

2"/51mm

 

 

 

 

 

 

ALCOVE INSTALLATION / INSTALLATION DE L' ALCÔVE:

 

 

 

 

 

 

 

Max. Alcove Depth: / La profondeur maximum de l'alcôve

36"/914mm

 

 

 

 

 

 

 

 

 

 

 

 

 

Back Wall to stove / Mur Arrière du poêle

2"/51mm

 

 

 

 

 

 

B

Side Wall to Cast Top / Mur De Côté du haut

6"/152mm

 

 

 

 

 

 

C

Unit corner to diagonal wall /

2" (51mm)

 

 

 

 

 

 

F

Top of Unit to Combustibles / Du poêle du haut combustibles

12.5"/318mm

 

 

 

 

 

 

 

Alcove vertical installation / Installation verticale de l'alcôve

 

 

 

 

 

 

 

D

Back Wall to Flue Pipe / Mur Arrière tuyau rigide

3"/76mm

 

H*

 

 

 

FLOOR PROTECTION / PROTECTION DU SOL

 

 

 

 

*Non-combustible floor protection must extend beneath the flue pipe when installed with

*Un protecteur incombustible de plancher doit s'étendre sous le conduit de cheminée pour une

 

 

G

G

horizontal venting or under the Top Vent Adapter with vertical installation.

installation de ventilation horizontale ou sous un adapteur de ventilation de dessus pour une

 

 

RECOMMENDED IN USA; REQUIRED IN CANADA

 

 

 

 

installation verticale. ÉTATS-UNIS - RECOMMANDÉ; CANADA - REQUIRENT

 

I

Floor protector must be noncombustible material, extending beneath heater and to the

Le poêle doit être placé sur une assise non combustible s’étendant tout autour de lui, comme les

G = 2"/51mm

front/sides/rear as indicated. Measure front distance (I) from the surface of the glass door.

schémas l’indiquent. Mesurez la distance du devant (I) de la surface de la porte vitrée.

H* = 2"/51mm

U.S. ENVIRONMENTAL PROTECTION AGENCY This model is exempt from EPA certification under 40 CFR 60.531 by definition [Wood Heater (A) "Air-to-Fuel Ratio"].

I = 6"/152mm

2008

2009

2010

JAN

FEB

MAR

APR

MAY

JUNE JULY

AUG

SEPT

OCT

NOV DEC

 

 

 

 

1445 Highway North

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Colville, WA 99114

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.quadrafire.com

 

 

 

 

 

Made in China/Fait Aux Chine

 

 

 

 

 

 

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

 

 

 

7014-079

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mfg Date

Page

7014-082D

September 1, 2008

Image 2
Contents Classic BAY 1200 Pellet Stove Hot glass will cause burnsBehind left side curtain on outside of hopper wall Testing Lab & Report NumberCB 1200 Pellet Stove Serial Number ModelTable of Contents Listing and Code Approvals Getting Started Design, Installation & Location ConsiderationsFire Safety Appliance LocationCB 1200 Pellet Stove Tools And Supplies Needed Inspect Appliance & Components and Pre-Use Check ListDimensions and Clearances Appliance DimensionsCB 1200 Pellet Stove Clearances to Combustibles UL and ULC Hearth Pad Requirements Exception for Horizontal InstallationsCB 1200 Pellet Stove Hearth Pad Requirements UL and ULC Vent Information Example of 3 Elbow-Rear Vent Termination Calculaton Pipe Selection ChartCB 1200 Pellet Stove Equivalent Feet of Pipe 5Venting Systems AlcoveCB 1200 Pellet Stove Through The Wall Straight OutDegree CB 1200 Pellet Stove Vertical Through The Wall & VerticalMasonry Alternate MasonryMobile Home Outside Air Kit Instructions Rear Installation Floor InstallationAppliance Set-Up Installing the Top Vent Adapter CB 1200 Pellet Stove Top Vent Adapter InstallationRear Vent and Rear Vent to Top Vent Adapter Installation See FigureCB 1200 Pellet Stove Optional Brick Set Installation Brick Clip InstallationTop Log, Left Installing Logo Nickel OnlyCharred Areas in the Back RightTo install door Door InstallationCB 1200 Pellet Stove Thermostat Installation To adjust latchesOperating Instructions Fuel Size And Material General Operating InformationFeed Rate Adjustment Instructions Starting Your First FireFrequently Asked Questions CB 1200 Pellet Stove Ignition CyclesPossible Cause Corrective Action TroubleshootingSymptom Page Page Frequency Daily Weekly Monthly Yearly Quick Reference Maintenance Chart10Maintaining & Servicing Your Appliance Types of FuelCleaning Heat Exchanger Chambers & Drop Tube Cleaning Firepot with Cleaning Rod & Firepot ScraperCleaning Ash Pan Ash Removal from FireboxCleaning the Glass Cleaning Beneath Heat ExchangerCleaning Exhaust Path Cleaning the HopperCleaning the Top Vent Adapter Preparing Firebox for Non-Burn Season Frequency YearlyCB 1200 Pellet Stove High Ash Fuel Content Maintenance Convection Blower ReplacementRe-install blower to blower housing Exhaust Blower Replacement Remove existing blowerInstall new blower Glass Replacement Replacing Side GlassReference Materials Component Function & LocationSnap Disc #1 Convection Blower 145F Vacuum SwitchWiring Harness See .1 below Snap Disc #2 Thermostat Override 200FCleaning Rods Heat Exchanger Tubes CB 1200 Pellet Stove Component LocationsGlass Size Sides 8 wide x 11 high CB 1200 Pellet Stove Exploded ViewsGlass Size Center 13-7/8 wide x 11 high Nbr Description CB 1200 Pellet Stove CB 1200 Pellet Stove Service Parts and Accessories Item # Parts Alphabetical OrderItem # Service Parts Alphabetical Order Accessories ApplianceCB 1200 Pellet Stove Service And Maintenance Log Date of Service Performed By Description of ServiceCB 1200 Pellet Stove Homeowner’s Notes CB 1200 Pellet Stove Warranty Policy CONDITIONS, Exclusions & Limitation of LiabilityHearth & Home Technologies Limited Warranty Cont’d Contact Information