CB 1200 Pellet Stove

Symptoms

Possible Cause

Corrective Action

Convection blower fails to

#1 snap disc defective.

Replace snap disc.

start.

Blower not plugged in.

Check that blower is plugged into wire har-

 

 

 

ness.

 

Blower is defective.

Replace blower.

 

Control box is defective.

Replace control box.

Exhaust blower fails to

Blower not plugged in.

Check that blower is plugged into wire har-

start or does not shut off.

 

ness.

 

Blower is clogged with ash.

Clean exhaust system.

 

Blower is defective.

Replace blower.

 

Control box is defective.

Replace control box.

Large, lazy flame, orange

Dirty appliance.

Clean unit, including firepot, heat exchang-

color. Black ash on glass.

Poor fuel quality, high ash content.

ers and venting system. Remove stainless

 

 

steel baffle from firebox to clean ash from

 

 

on top of baffle. Clean behind rear brick

 

 

panels. Change fuel brand to premium.

 

Firepot clean-out plate not completely

Check that firepot clean-out plate is fully

 

closed.

closed.

 

 

Reduce feed rate using feed rate adjustment

 

Excessive amount of fuel.

control rod located inside hopper.

Nuisance shutdowns.

Low flame.

Increase feed by opening feed rate adjust-

 

 

ment control rod located inside hopper.

 

Sawdust buildup in hopper.

Clean hopper, see page 30.

 

Feed motor is reversing.

Check for good connections between feed

 

 

motor and wire harness.

 

Defective thermocouple.

Replace thermocouple.

 

Defective control box.

Replace control box.

 

Firepot more than 1/2 full.

See page 31 for detailed instructions for

 

 

“High Ash Fuel Content Management”

Appliance calls for heat.

Thermocouple is defective or not properly

Check connections on thermocouple or

Call light illuminates.

plugged in.

replace if defective.

Exhaust blower starts.

 

A flashing yellow light on the control box

No feed or igniter.

 

indicates a problem with the thermocouple.

 

Defective control box

Replace control box.

September 1, 2008

7014-082D

Page 27

Image 27
Contents Hot glass will cause burns Classic BAY 1200 Pellet StoveSerial Number Model Testing Lab & Report NumberCB 1200 Pellet Stove Behind left side curtain on outside of hopper wallTable of Contents Listing and Code Approvals Appliance Location Design, Installation & Location ConsiderationsFire Safety Getting StartedInspect Appliance & Components and Pre-Use Check List CB 1200 Pellet Stove Tools And Supplies NeededAppliance Dimensions Dimensions and ClearancesCB 1200 Pellet Stove Clearances to Combustibles UL and ULC Exception for Horizontal Installations CB 1200 Pellet Stove Hearth Pad Requirements UL and ULCHearth Pad Requirements Vent Information Pipe Selection Chart CB 1200 Pellet Stove Equivalent Feet of PipeExample of 3 Elbow-Rear Vent Termination Calculaton Alcove 5Venting SystemsStraight Out DegreeCB 1200 Pellet Stove Through The Wall Through The Wall & Vertical CB 1200 Pellet Stove VerticalAlternate Masonry MasonryMobile Home Rear Installation Floor Installation Appliance Set-UpOutside Air Kit Instructions See Figure CB 1200 Pellet Stove Top Vent Adapter InstallationRear Vent and Rear Vent to Top Vent Adapter Installation Installing the Top Vent AdapterBrick Clip Installation CB 1200 Pellet Stove Optional Brick Set InstallationRight Installing Logo Nickel OnlyCharred Areas in the Back Top Log, LeftTo adjust latches Door InstallationCB 1200 Pellet Stove Thermostat Installation To install doorFuel Size And Material General Operating Information Operating InstructionsStarting Your First Fire Feed Rate Adjustment InstructionsCB 1200 Pellet Stove Ignition Cycles Frequently Asked QuestionsTroubleshooting SymptomPossible Cause Corrective Action Page Page Types of Fuel Quick Reference Maintenance Chart10Maintaining & Servicing Your Appliance Frequency Daily Weekly Monthly YearlyAsh Removal from Firebox Cleaning Firepot with Cleaning Rod & Firepot ScraperCleaning Ash Pan Cleaning Heat Exchanger Chambers & Drop TubeCleaning the Hopper Cleaning Beneath Heat ExchangerCleaning Exhaust Path Cleaning the GlassPreparing Firebox for Non-Burn Season Frequency Yearly Cleaning the Top Vent AdapterConvection Blower Replacement CB 1200 Pellet Stove High Ash Fuel Content MaintenanceExhaust Blower Replacement Remove existing blower Install new blowerRe-install blower to blower housing Replacing Side Glass Glass ReplacementComponent Function & Location Reference MaterialsSnap Disc #2 Thermostat Override 200F Vacuum SwitchWiring Harness See .1 below Snap Disc #1 Convection Blower 145FCB 1200 Pellet Stove Component Locations Cleaning Rods Heat Exchanger TubesCB 1200 Pellet Stove Exploded Views Glass Size Center 13-7/8 wide x 11 highGlass Size Sides 8 wide x 11 high Nbr Description CB 1200 Pellet Stove Item # Parts Alphabetical Order CB 1200 Pellet Stove Service Parts and AccessoriesItem # Service Parts Alphabetical Order Appliance AccessoriesDate of Service Performed By Description of Service CB 1200 Pellet Stove Service And Maintenance LogCB 1200 Pellet Stove Homeowner’s Notes CONDITIONS, Exclusions & Limitation of Liability CB 1200 Pellet Stove Warranty PolicyHearth & Home Technologies Limited Warranty Cont’d Contact Information