Quadra-Fire CB1200-B owner manual Listing and Code Approvals

Page 4

CB1200 Pellet Stove

Listing and Code Approvals

R

A. Appliance Certification

E. BTU & Efficiency Specifications

Model

CB1200 Pellet Stove

Laboratory

OMNI Test Laboratories, Inc.

Report No.

061-S-21-4

Type

Solid Fuel Room Heater/Pellet Fuel

 

BurningType

Standard

ASTM E1509-95, ULC S627-M93 and

 

ULC/ORD-C1482-M1990 Room Heater

 

Pellet Fuel Burning type and (UM) 84-

 

HUD, Mobile Home Approved.

State Listing

Colorado, Listed 09-13-05

Emissions Rating

0..9 grams/hr

*BTU Output

14,000 - 40,000 / hr

Heating Capacity

up to 2,500 sq. ft. depending

 

on climate zone

Hopper Capacity

80 lbs

Fuel

Wood Pellets or Shelled Corn

Shipping Weight

349 lbs

*BTU output will vary, depending on the brand of fuel you use in your stove. Consult your Quadra-Fire dealer for best results.

B. Mobile Home Approved

This appliance is approved for mobile home installations when not installed in a sleeping room and when an outside combustion air inlet is provided. The structural integrity of the mobile home floor, ceiling, and walls must be maintained. The appliance must be properly grounded to the frame of the mobile home and use only Listed pellet vent Class “L” or “PL” connector pipe. A Quadra-Fire Outside Air Kit must be installed in a mobile home installation.

C. Glass Specifications

This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass.

NOTE: This installation must conform with local codes. In the absence of local codes you must comply with the ASTM

E1509, ULC S627-M93, ULC/ORD-C-1482-M1990, (UM) 84-HUD

D. Electrical Rating

115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps

NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifications and/or price without notice.

Page

7014-082D

September 1, 2008

Image 4
Contents Classic BAY 1200 Pellet Stove Hot glass will cause burnsTesting Lab & Report Number CB 1200 Pellet StoveBehind left side curtain on outside of hopper wall Serial Number ModelTable of Contents Listing and Code Approvals Design, Installation & Location Considerations Fire SafetyGetting Started Appliance LocationCB 1200 Pellet Stove Tools And Supplies Needed Inspect Appliance & Components and Pre-Use Check ListDimensions and Clearances Appliance DimensionsCB 1200 Pellet Stove Clearances to Combustibles UL and ULC CB 1200 Pellet Stove Hearth Pad Requirements UL and ULC Exception for Horizontal InstallationsHearth Pad Requirements Vent Information CB 1200 Pellet Stove Equivalent Feet of Pipe Pipe Selection ChartExample of 3 Elbow-Rear Vent Termination Calculaton 5Venting Systems AlcoveDegree Straight OutCB 1200 Pellet Stove Through The Wall CB 1200 Pellet Stove Vertical Through The Wall & VerticalMasonry Alternate MasonryMobile Home Appliance Set-Up Rear Installation Floor InstallationOutside Air Kit Instructions CB 1200 Pellet Stove Top Vent Adapter Installation Rear Vent and Rear Vent to Top Vent Adapter InstallationInstalling the Top Vent Adapter See FigureCB 1200 Pellet Stove Optional Brick Set Installation Brick Clip InstallationInstalling Logo Nickel Only Charred Areas in the BackTop Log, Left RightDoor Installation CB 1200 Pellet Stove Thermostat InstallationTo install door To adjust latchesOperating Instructions Fuel Size And Material General Operating InformationFeed Rate Adjustment Instructions Starting Your First FireFrequently Asked Questions CB 1200 Pellet Stove Ignition CyclesSymptom TroubleshootingPossible Cause Corrective Action Page Page Quick Reference Maintenance Chart 10Maintaining & Servicing Your ApplianceFrequency Daily Weekly Monthly Yearly Types of FuelCleaning Firepot with Cleaning Rod & Firepot Scraper Cleaning Ash PanCleaning Heat Exchanger Chambers & Drop Tube Ash Removal from FireboxCleaning Beneath Heat Exchanger Cleaning Exhaust PathCleaning the Glass Cleaning the HopperCleaning the Top Vent Adapter Preparing Firebox for Non-Burn Season Frequency YearlyCB 1200 Pellet Stove High Ash Fuel Content Maintenance Convection Blower ReplacementInstall new blower Exhaust Blower Replacement Remove existing blowerRe-install blower to blower housing Glass Replacement Replacing Side GlassReference Materials Component Function & LocationVacuum Switch Wiring Harness See .1 belowSnap Disc #1 Convection Blower 145F Snap Disc #2 Thermostat Override 200FCleaning Rods Heat Exchanger Tubes CB 1200 Pellet Stove Component LocationsGlass Size Center 13-7/8 wide x 11 high CB 1200 Pellet Stove Exploded ViewsGlass Size Sides 8 wide x 11 high Nbr Description CB 1200 Pellet Stove CB 1200 Pellet Stove Service Parts and Accessories Item # Parts Alphabetical OrderItem # Service Parts Alphabetical Order Accessories ApplianceCB 1200 Pellet Stove Service And Maintenance Log Date of Service Performed By Description of ServiceCB 1200 Pellet Stove Homeowner’s Notes CB 1200 Pellet Stove Warranty Policy CONDITIONS, Exclusions & Limitation of LiabilityHearth & Home Technologies Limited Warranty Cont’d Contact Information