Quadra-Fire CB1200-B owner manual Door Installation, CB 1200 Pellet Stove Thermostat Installation

Page 21

R

I. Door Installation

To install door:

1.Carefully remove door from packaging.

2.Line up hinges with hinge pins on appliance body, and slide door down until it sits securely on pins. Figure 21.1.

3.If door is plated, be sure to clean all plated surfaces and glass with a glass cleaner to ensure all oils are removed before your first burn.

4.Remove all labels from glass before burning appliance.

To adjust latches:

1.

Close door securely.

2.

Place rod in slot on the bracket on the door and close

 

latch.

3.

Latch must close tightly enough to ensure an airtight

 

seal between the door and the body of the appliance. To

 

increase tension on the latch, turn the rod clockwise a few

 

turns, then attempt to close the latch, until it is snug. Do not

 

overtighten; you should be able to close the latch with your

 

hand. Figure 21.2.

4.

After adjusting the latch, place a Phillips head screw driver

 

in the end of the rod, and tighten the nut with a wrench.

 

This will maintain the correct tension on the rod and latch.

Hinge Pin

Hinge

Figure 21.1

Rod and nut

Rod and nut

Figure 21.2

CB 1200 Pellet Stove

J. Thermostat Installation

1. A 12 volt AC thermostat is required to operate this pellet appliance. You may use the included wall mount thermo- stat or purchase an optional programmable thermostat or remote control. It is equipped with an adjustable heat anticipator. The current rating is .05 amps. The anticipator needs to be adjusted to the lowest setting available.

2.When mounting a thermostat on a wall, be sure to follow your thermostat installation instructions carefully.

NOTE: Thermostat must be mounted level for accurate readings. The thermostat should be mounted on an inside wall and not in direct line with the appliance convection air.

NOTE: If the thermostat is located too close to the appliance, you may need to set the temperature setting slightly higher to maintain the desired temperature in your home.

3.There is a 4 screw terminal block located on the back lower left corner of the stove directly above the power cord inlet. The center 2 screws are for the thermostat wires.

Power Outlet

Terminal Block.

Center 2 screws for

Thermostat Wires

Figure 21.3

Caution

Shock hazard.

• Do NOT remove grounding prong from plug.

Plug directly into properly grounded 3 prong receptacle.

Route cord away from appliance.

Do NOT route cord under or in front of appliance.

September 1, 2008

7014-082D

Page 21

Image 21
Contents Hot glass will cause burns Classic BAY 1200 Pellet StoveCB 1200 Pellet Stove Testing Lab & Report NumberBehind left side curtain on outside of hopper wall Serial Number ModelTable of Contents Listing and Code Approvals Fire Safety Design, Installation & Location ConsiderationsGetting Started Appliance LocationInspect Appliance & Components and Pre-Use Check List CB 1200 Pellet Stove Tools And Supplies NeededAppliance Dimensions Dimensions and ClearancesCB 1200 Pellet Stove Clearances to Combustibles UL and ULC Exception for Horizontal Installations CB 1200 Pellet Stove Hearth Pad Requirements UL and ULCHearth Pad Requirements Vent Information Pipe Selection Chart CB 1200 Pellet Stove Equivalent Feet of PipeExample of 3 Elbow-Rear Vent Termination Calculaton Alcove 5Venting SystemsStraight Out DegreeCB 1200 Pellet Stove Through The Wall Through The Wall & Vertical CB 1200 Pellet Stove VerticalAlternate Masonry MasonryMobile Home Rear Installation Floor Installation Appliance Set-UpOutside Air Kit Instructions Rear Vent and Rear Vent to Top Vent Adapter Installation CB 1200 Pellet Stove Top Vent Adapter InstallationInstalling the Top Vent Adapter See FigureBrick Clip Installation CB 1200 Pellet Stove Optional Brick Set InstallationCharred Areas in the Back Installing Logo Nickel OnlyTop Log, Left RightCB 1200 Pellet Stove Thermostat Installation Door InstallationTo install door To adjust latchesFuel Size And Material General Operating Information Operating InstructionsStarting Your First Fire Feed Rate Adjustment InstructionsCB 1200 Pellet Stove Ignition Cycles Frequently Asked QuestionsTroubleshooting SymptomPossible Cause Corrective Action Page Page 10Maintaining & Servicing Your Appliance Quick Reference Maintenance ChartFrequency Daily Weekly Monthly Yearly Types of FuelCleaning Ash Pan Cleaning Firepot with Cleaning Rod & Firepot ScraperCleaning Heat Exchanger Chambers & Drop Tube Ash Removal from FireboxCleaning Exhaust Path Cleaning Beneath Heat ExchangerCleaning the Glass Cleaning the HopperPreparing Firebox for Non-Burn Season Frequency Yearly Cleaning the Top Vent AdapterConvection Blower Replacement CB 1200 Pellet Stove High Ash Fuel Content MaintenanceExhaust Blower Replacement Remove existing blower Install new blowerRe-install blower to blower housing Replacing Side Glass Glass ReplacementComponent Function & Location Reference MaterialsWiring Harness See .1 below Vacuum SwitchSnap Disc #1 Convection Blower 145F Snap Disc #2 Thermostat Override 200FCB 1200 Pellet Stove Component Locations Cleaning Rods Heat Exchanger TubesCB 1200 Pellet Stove Exploded Views Glass Size Center 13-7/8 wide x 11 highGlass Size Sides 8 wide x 11 high Nbr Description CB 1200 Pellet Stove Item # Parts Alphabetical Order CB 1200 Pellet Stove Service Parts and AccessoriesItem # Service Parts Alphabetical Order Appliance AccessoriesDate of Service Performed By Description of Service CB 1200 Pellet Stove Service And Maintenance LogCB 1200 Pellet Stove Homeowner’s Notes CONDITIONS, Exclusions & Limitation of Liability CB 1200 Pellet Stove Warranty PolicyHearth & Home Technologies Limited Warranty Cont’d Contact Information