Quadra-Fire 21M-ACC owner manual Glass Replacement, When cleaning glass

Page 29

R

2100 Millennium Wood Stove (ACC)

 

CAUTION

 

Handle glass assembly with care.

Glass

When cleaning glass:

Assembly

• Avoid striking, scratching or

 

 

slamming glass.

Do NOT clean glass when hot.

Do NOT use abrasive cleaners.

Use a hard water deposit glass cleaner on white film.

Use commerical oven cleaner on heavier deposits.

Remove all residue of oven cleaner or will permanently stain glass on next firing.

Refer to maintenance instructions.

C. Glass Replacement

1. Ensure that the fire is out and the appliance is cool to the touch.

2.Protect a table or counter top with padding or towels. Protect your hands and wear gloves to prevent injury.

3.Remove the door with the broken glass by lifting the door up and off of the hinges.

4.Lay door face down on a table or counter making sure the handle hangs over the edge so the door lays flat, on a soft surface.

5.Remove the screws from each glass retainer and remove the glass. (If screws are difficult to remove, soak with penetrating oil first).

6.Center the glass with edges evenly overlapping the opening in the door, (i.e. same space top and bottom, left and right sides).

7.Replace the glass retainers. Be careful not to cross thread the screws.

8.Tighten each retainer just a few turns until each is secured. Check again for centering of glass in door frame. Continue to tighten each retainer alternately, a few turns at a time, until the glass is secure. DO NOT OVERTIGHTEN.

9.Replace the door on the appliance.

Quadra-Fire stoves are equipped with ceramic super heat- resistant glass, which can only be broken by impact or misuse. Do not slam stove door or impact the glass. When closing door, make sure that logs do not protrude against the glass. Inspect glass regularly. If you find a crack or break, immediately put the fire out and return the door to your dealer for replacement of glass before further use.

WARNING

Handle glass with care.

• Inspect the gasket to ensure it is

Glassundamaged.

Assembly

Do NOT strike, slam or scratch glass.

Do NOT operate appliance with glass & door assembly removed.

Do NOT operate with glass cracked, broken or scratched.

WARNING

Fire Risk.

Injury Risk.

Use only glass specified in manual.

DO NOT REPLACE with any other material. Glass breakage will occur.

May 5, 2011

7039-131H

Page 29

Image 29
Contents 7039-131H May 5 Hot glass will cause burnsMfg. Date 7039-131H May 5 Millennium Wood Stove ACCSerial No Model Name Test Lab & Report No Table of Contents Glass Specifications Appliance Certification BTU & Efficiency SpecificationsListing and Code Approvals Mobile Home ApprovedGetting Started Fire SafetyMillennium Wood Stove ACC Negative Pressure Appliance needs to draft properly for safetyVenting Systems Millennium Wood Stove ACC Flue Draft ConsiderationsTools And Supplies Needed Inspect Appliance & Components Pre-Burn Check ListMasonry Chimney Millennium Wood Stove ACC Typical Stove SystemsAppliance Dimensions Dimensions and ClearancesBackwall / Sidewall Corner Installation Hearth Protection Requirements InstallationRSee Figure USA required Canada recommendedFloor Installation Alternative In some instances you Millennium Wood Stove ACC Outside Air Kit InstallationItems Needed for Installation not supplied 13-15/16 in mm Blower OptionalChimney Requirements Chimney ConnectorVenting Components Chimney Systems ThimbleAir Clearances ComponentsInstructions Solid Pack Chimney with Metal Supports as a ThimbleSingle wall connector or stove pipe Installing Chimney ComponentsSolid Pack Chimney with Metal Supports as a Thimble Cont’d Chimney Height / Rise and RunRule Millennium Wood Stove ACC Chimney Termination RequirementsPitched Roof Flat RoofMobile Home Installation Appliance Set-Up Door Handle Assembly Adjusting The Blower Speed ControlOver-Firing Your Appliance Wood Selection & Storage Cont’d Operating InstructionsBurning Process Wood Selection & StorageAir Controls Automatic Combustion Control ACCBurn Rates and Operating Efficiency Millennium Wood Stove ACC Building a Fire Incorrect Positions Millennium Wood Stove ACC Blower Operating Instructions Initial cold start-up and all Burn SettingsOpacity Smoke Snap Disc LocationAppliance Millennium Wood Stove ACC Frequently Asked QuestionsOdor from appliance Maintaining & Servicing Your Appliance Quick Reference Maintenance GuideCreosote Chimney Cleaning Millennium Wood Stove ACC General MaintenanceGlass Cleaning Frequency As desired Disposal of AshesWhen cleaning glass Glass ReplacementTo your authorized dealer Millennium Wood Stove ACC Firebrick ReplacementBaffle Correct Blanket & Baffle Position onReplacing Tube Channel Assembly Millennium Wood Stove ACC Tube Channel Assembly ReplacementRemoving Tube Channel Assembly Start Fire Problems Possible Cause Solution TroubleshootingMillennium Wood Stove 21M-ACC21M-ACC Stocked 21M-ACC Date of Service Performed By Description of Service Millennium Wood Stove ACC Service And Maintenance LogMillennium Wood Stove ACC Service And Maintenance Log Cont’d Millennium Wood Stove ACC Homeowner’s Notes Millennium Wood Stove ACC Homeowner’s Notes Millennium Wood Stove ACC Warranty Policy Millennium Wood Stove ACC Contact Information