WARNING! Risk of Asphyxiation!

Never install in a sleeping room. Consumes oxygen in the the room.

1.An outside air intake must be provided for the combus- tion air and must:

Remain clear of leaves, debris, ice and/or snow.

Be unrestricted while the appliance is in use to pre- vent room air starvation which causes smoke spill- age.

Smoke spillage can also set off smoke alarms.

2.The combustion air duct system must be made of metal and it must:

Permit zero clearance to combustible construction.

Prevent material from dropping into the inlet or into the area beneath the dwelling.

Must contain a rodent screen.

3.The appliance must be secured to the mobile home structure by bolting it to the fl oor. See page 33 for detailed instructions on securing fireplace to the

oor.

4.The appliance must be grounded with #8 solid copper grounding wire or equivalent, terminated at each end with an NEC approved grounding device.

5.Refer to Clearances to Combustibles and fl oor protec- tion requirements in Section 6 for listings to combus- tibles and appropriate chimney systems.

6.Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the the exterior of the structure.

7.Follow the chimney manufacturer’s instructions when installing the vent system for use in a mobile home.

8.Installation shall be in accordance with the Manufacturers Home & Safety Standard (HUD) CFR 3280, Part 24.

CAUTION

THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE MAIN- TAINED

Do NOT cut through:

Floor joist, wall, studs or ceiling trusses.

Any supporting material that would affect the structural integrity.

This unit is to be connected to a factory-built chimney conforming to CAN/ULC-S629, Standard for 650°C Factory-Built Chimneys.

For removal of the chimney for mobile home transporta- tion, contact the proper transportation offi cials.

SparkArrestor Cap

Storm Collar

Roof Flashing

Joist Shield/Firestop

Approved Class L

or PL Pellet Vent

Figure 46.1

December 6, 2011

7051-158B

Page 47

Image 47
Contents Hot glass will cause burns Natural Curved Tuscan StudioSerial Number Label Edge 60 Pellet FireplaceTable of Contents Edge 60 Pellet Fireplace Edge 60 Pellet Fireplace Listing and Code Approvals Operating Instructions User’s GuideFuel Material and Fuel Storage Edge 60 Pellet Fireplace Fire SafetyCombustible/Non-Combustible Materials Before Your First Fire Power SwitchAuto-Clean Firepot System General Operating InformationIgnition Cycles Edge 60 Pellet Fireplace Filling the Hopper with FuelStarting Your First Fire Soft Start Cycle SS-Low / SS-Med Auto-Clean CycleAutomatic Mode Manual ModeBattery Back-up System Optional Clear Space Edge 60 Pellet Fireplace Battery Back-up System Cont’dBefore Servicing Your Appliance Quick Reference Maintenance ChartCleaning or Inspection Maintaining & Servicing Your ApplianceEdge 60 Pellet Fireplace High Ash Fuel Content Maintenance Accessing Components for MaintenanceDisposal of Ashes Frequency As needed Auto-Clean System Inspection & CleaningCleaning Ash Pan Shop Vac* Example Micro Cleaning Kit Cleaning Heat Exchanger, Drop Tube & ExhaustClinker Cleaning Exhaust Blower Do Not Use Lubrication Cleaning the HopperCleaning Convection Blower Do Not Use Lubrication Cleaning the GlassChimney Inspection and Cleaning Frequently Asked Questions Troubleshooting for HomeownerPossible Cause Corrective Action Floor Support Getting StartedAppliance Location Description Checklist to Help Determine LocationTools And Supplies Needed Inspect Appliance and ComponentsRecommended Sequence Material is installed. See Item GCrush Hazard Hearth Extension Framing Dimensions & ClearancesOutside Air Kit is Required for All installations Recommended LocationsFrame the Fireplace Sealing at the Penetration of Building Envelope27.1 Edge 60 Pellet Fireplace Construct the ChaseProtrudes Beyond the Mounting Frame Edge 60 Pellet Fireplace Finishing MaterialFlush with the Mounting Frame Behind the Mounting FrameOpening Clearances for the Curved Tuscan and Natural Fronts Opening Clearances for the Studio Front Rise to run ratio Edge 60 Pellet Fireplace Mantel Fuel Loading ClearancesCombustible Materials Edge 60 Pellet Fireplace Non-Combustible MaterialsSub-Floor Material & Securing Fireplace Crush Hazard Installation of FireplacePosition the Fireplace Shock Hazard Power Supply Cord Wall Control WireBack Side of Wall Control with Cover Off Vertical InstallationVertical Installation Cont’d Horizontal Installation Termination must exhaust above air inlet elevation Vent InformationVenting Termination Minimum Requirements Do not Terminate VentEdge 60 Pellet Fireplace Avoiding Smoke and Odors Edge 60 Pellet Fireplace Negative Pressure Draft Example of 3 Elbow-Rear Vent Termination Calculation Edge 60 Pellet Fireplace Chimney and Exhaust ConnectionEquivalent Feet of Pipe Altitude in Thousands of Feet Edge 60 Pellet Fireplace Pipe Selection ChartOutside Air Inlet Locations Left Rear Corner Right Rear Corner Rear of FireplaceInstall Outside Air Kit Edge 60 Pellet Fireplace Outside Air Kit InstallationThrough the Wall & Vertical Exterior Vertical Interior Typical InstallationDegree Choose which one is best for your installationEdge 60 Pellet Fireplace Through the Wall Straight OutMobile Home Installation Rebox. Figures 47.3 Optional Log Set Placement InstructionsAppliance Set-Up Rebox. Figures 47.1Front Installation Glass Replacement Replacement PartsConvection Blower Replacement Baffl e Removal & Replacement Error Message Troubleshooting For InstallersRear View Fireplace DimensionsReference Materials Top ViewEdge 60 Pellet Fireplace Component Functions Overheat Sensor Snap Disc Power SupplyPower Switch Vacuum SwitchView of Left Rear Edge 60 Pellet Fireplace Component LocationsDate of Service Performed By Description of Service Edge 60 Pellet Fireplace Service And Maintenance LogHearth & Home Technologies Contact Information

7051-158B specifications

The Quadra-Fire 7051-158B is a premier wood-burning fireplace designed for homeowners seeking an efficient and aesthetically pleasing heating solution. This fireplace combines advanced technology with classic design, making it an exceptional choice for any living space.

One of the key features of the 7051-158B is its impressive heating capability. With a maximum heat output of up to 75,000 BTUs, it can effectively warm areas up to 2,500 square feet. This makes it ideal for both large homes and open-concept areas. The fireplace is equipped with a large firebox that can accommodate logs up to 24 inches, allowing for longer burn times and fewer reloads, thereby enhancing convenience for users.

Efficiency is a major focus of the Quadra-Fire 7051-158B. The unit boasts an impressive EPA-certified efficiency rating, which signifies that it burns wood cleanly and effectively, producing minimal smoke and emissions. This not only benefits the environment but also maximizes the warmth generated from each log of wood burned. The unit is designed to maintain a consistent temperature with its advanced combustion technology, which ensures a clean burn while maximizing heat output.

To enhance user experience, the 7051-158B incorporates several technological features. One such innovation is the Quadra-Fire's patented Four-Point Burn Technology, which promotes optimal airflow and combustion. This technology results in a more complete burn, reducing the amount of creosote buildup in the chimney and enhancing safety. The fireplace also comes with an easy-to-use air control system, allowing homeowners to easily adjust the amount of air entering the firebox for customized heat and burn rates.

From a design perspective, the Quadra-Fire 7051-158B offers a perfect blend of traditional and contemporary aesthetics. The elegant exterior is available in various finishes, enabling homeowners to choose an option that complements their decor. Large glass doors provide a captivating view of the flames, creating a cozy ambiance in any room.

In conclusion, the Quadra-Fire 7051-158B stands out as a top choice for wood-burning fireplaces. With its efficient heating capabilities, cutting-edge technology, and beautiful design, it is sure to enhance both the comfort and appeal of your home. Whether you are looking to heat a large space or simply enjoy the warmth of a wood fire, this fireplace provides a reliable and stylish solution.