Vermont Casting RDVOD manual Connect the Gas Supply Line

Page 20

 

Rear Log

 

Bracket

 

LG158

Fig. 38

Radiance firebox.

Right Log

Right Rear Log

Left Rear Log

Left Bracket

Decorative

Right

 

 

Grate

Bracket

LG156

Fig. 39 Install the left and right rear logs and the right log.

4.Install the right log by engaging hole on the bottom with pin on the right rear log. (Fig. 40) Set the bottom of the log on the bracket and bring forward to come in contact with decorative grate on right.

5.Loosely sprinkle the lava rocks directly on top of the burner just behind decorative grate. (Fig. 41) Use the lava rock to cover brackets on the burner. Do not place lava rocks toward back of burner. The lava rock is shipped inside the bag assembly.

Radiance Direct Vent /Natural Vent Gas Heater

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Log rests on

 

 

Lava Rock

 

 

decorative grate

 

 

 

LG155

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 40

Completed log installation.

 

Left Rear Log

Top View

Right Rear

Log

 

 

 

Decorative Grate

 

Lava rock may

 

be placed in

LG160

 

 

this area

 

 

 

Fig. 41

Lava rock placement.

 

Connect the Gas Supply Line

Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The Radiance may be converted from one gas to another using the appropri- ate Fuel Conversion Kit listed on page 30.

In the U.S.; Gas connection should be made in ac- cordance with current National Fuel Gas Code, ANSI Z223.1/NFPA 54. Since some municipalities have addi- tional local codes, be sure to consult your local authority.

In Canada; consult the local authority and CSA-B149.1 installation code.

Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing.

Light the pilot according to the directions on Page 24, before going to the next step.

20004188

21

Image 20
Contents Radiance Direct Vent/Natural Vent Gas Heater Installation & Operating Instructions Radiance Direct Vent/Natural Vent Stove Dimensions Radiance dimensionsClearance Requirements Installation RequirementsLocating The Stove Hearth Requirements Wall Centerline from FloorWall and Ceiling Clearances Gas Specifications Gas Inlet and Manifold PressuresHigh Elevations Horizontal Termination Direct Vent onlyVent Termination Clearances Restictor Plate is used on Direct Vent installations onlyVertical Termination Direct Vent only Location of Vent Termination Canadian Installations US Installations General Venting Information Termination LocationVenting Requirements Natural Vent Only Plate supplied with the stove is not usedVenting Requirements and Options Direct Vent only Approved Vent System ComponentsAssembly Procedures Parts Bag ContentsTools Required Unpack and Assemble LegsInstall the Optional Fan Remove rear shroudVenting System Assembly Direct Vent General Information Install the Vent Adapter PipeFor Canadian installations The venting system must Attach the Inner Vent Assembly to the stoveDiscard the inner starter pipe shipped with the log Side Wall Termination AssemblyInstall the Outer Adapter Pipe. Orient the verti Measure the horizontal length Vertical Through the Roof Vent Assembly Vent Termination Below GradeVenting System Assembly Natural Vent General Information Install firestops and attic insulation shieldInstall the Vent Pipe Install Log SetInstall the left and right rear logs and the right log Connect the Gas Supply LineInstall ON/OFF Switch Install the Mesh and GrilleBurner Information Thermostat Connection optionalFlame & Temperature Adjustment Flame CharacteristicsOperation Your First FireLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionShut Off Procedure Transmitter Operation Off ModeOn Manual Mode Delay Timer ModeLocal Path On Path Auto Path Auto Mode Fan Override During Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionAir Shutter Adjustment Injector Orifice Size MatrixAll Models Conversion to Natural Gas Input BTU/hMaintenance Check the Gas Flame Regularly Gasket ReplacementInspect the Vent System Annually Wiring Diagrams BLKRadiance Direct Vent/Natural Vent Gas Heater Rdvod DescriptionRadiance Direct Vent/Natural Vent Gas Heater Rdvod Fuel Conversion Kits Shell Enamel Parts Radiance Direct Vent / Natural VentOptional Accessories Limited Lifetime Warranty Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %