Vermont Casting Wall Centerline from Floor, Wall and Ceiling Clearances, Hearth Requirements

Page 5

Radiance Direct Vent/Natural Vent Gas Heater

Parallel Installation: Minimum Clearance

and Flue Centerline, Direct Vent and Natu-

ral Vent

42" (1070mm)

Min. Alcove Width

4" (102mm)

48"

(1220mm) Max. Alcove Depth

 

 

 

6"

 

 

 

6"

 

 

 

 

 

 

 

ST130

 

(150mm)

 

 

 

(150mm)

Fig. 3 Parallel installation, minimum back and side clear- ances, and flue centerlines.

Corner Installation: Minimum Clearance and Flue Centerline, Direct Vent & Natural Vent

18"

(457mm)

6"

(150mm)

18"

(457mm)

6"

(150mm)

ST129

Fig. 4 Corner installation, minimum corner clearances and flue centerline.

Wall Centerline from Floor

Direct Vent Only

A

ST131b

A

Effective Minimum

Centerline 57” (1448 mm) (CFM Corporation Pipe) 55” (1399 mm) (Simpson DuraVent Pipe)

Fig. 5 Minimum wall centerline.

Wall and Ceiling Clearances

Direct Vent Only

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

B

C

A

A: Rear Wall

4” (102 mm)

B: Min. Clearance

44” (1118 mm)*

C: Min. Alcove Height

72”

(1830 mm)*

D: Max. Alcove Depth

48”

(1220 mm)

Sidewall Clearance

6” (150 mm)

*needed for installing DuraVent Minimum Vent Kit #2792 or

CFM Corporation Minimum Vent Kit #7TFSMSK.

ST101b

 

Fig. 6 Dimensions and clearances to ceiling or alcove.

Hearth Requirements

The Radiance Heaters must be installed on rigid floor- ing. When the heater is installed directly on any com- bustible surface other than wood flooring, a metal or wood panel extending the full width and depth of the unit must be used as the hearth. There are no other hearth requirements.

66

20004188

Image 5
Contents Radiance Direct Vent/Natural Vent Gas Heater Installation & Operating Instructions Radiance dimensions Radiance Direct Vent/Natural Vent Stove DimensionsClearance Requirements Installation RequirementsLocating The Stove Hearth Requirements Wall Centerline from FloorWall and Ceiling Clearances Gas Inlet and Manifold Pressures Gas SpecificationsHigh Elevations Horizontal Termination Direct Vent onlyVent Termination Clearances Restictor Plate is used on Direct Vent installations onlyVertical Termination Direct Vent only Location of Vent Termination General Venting Information Termination Location Canadian Installations US InstallationsPlate supplied with the stove is not used Venting Requirements Natural Vent OnlyApproved Vent System Components Venting Requirements and Options Direct Vent onlyParts Bag Contents Assembly ProceduresTools Required Unpack and Assemble LegsRemove rear shroud Install the Optional FanInstall the Vent Adapter Pipe Venting System Assembly Direct Vent General InformationFor Canadian installations The venting system must Attach the Inner Vent Assembly to the stoveDiscard the inner starter pipe shipped with the log Side Wall Termination AssemblyInstall the Outer Adapter Pipe. Orient the verti Measure the horizontal length Vent Termination Below Grade Vertical Through the Roof Vent AssemblyInstall firestops and attic insulation shield Venting System Assembly Natural Vent General InformationInstall Log Set Install the Vent PipeConnect the Gas Supply Line Install the left and right rear logs and the right logInstall the Mesh and Grille Install ON/OFF SwitchBurner Information Thermostat Connection optionalFlame Characteristics Flame & Temperature AdjustmentOperation Your First FireTo Turn Off Gas To Heater Lighting and Operating InstructionsSymptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemTransmitter Operation Off Mode Shut Off ProcedureOn Manual Mode Delay Timer ModeLocal Path On Path Auto Path Fan Override During Auto Mode Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionInjector Orifice Size Matrix Air Shutter AdjustmentAll Models Conversion to Natural Gas Input BTU/hMaintenance Check the Gas Flame Regularly Gasket ReplacementInspect the Vent System Annually BLK Wiring DiagramsDescription Radiance Direct Vent/Natural Vent Gas Heater RdvodRadiance Direct Vent/Natural Vent Gas Heater Rdvod Shell Enamel Parts Radiance Direct Vent / Natural Vent Fuel Conversion KitsOptional Accessories Limited Lifetime Warranty Model EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings