Radiance Direct Vent/Natural Vent Gas Heater
All Models
22.Replace burner. Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base. Lower the right hand side down in to place. Make sure the burner is as far left as possible and the injector shoulders are inside the burner.
NOTE: It is very critical to keep the left burner leg, which holds the injectors, at a 90° angle to the base.
Center
Plunger
Blue - NGRed - LP
Motor Top Cap
Valve
LOCAL
FP1037b
(Fig. 61) This keeps the orifices aligned with the tubes inside burner. Failure to do so could affect the flame appearance and performance of the unit.
22.Place conversion label on valve.
23.Reinstall the right and left log bracket assembly.
24.Reinstall the rear log bracket.
25.Replace logs.
26.Replace glass and stove front.
Conversion is complete.
Fig. 60 Depress and turn center plunger.
Left Burner Leg |
Injector Orifices |
90° |
ST353a
Fig. 61 Remove and replace injector orifices.
Table 1. Injector Orifice Size Matrix
|
| Conversion to Natural Gas | Input (BTU/h) | ||||
Kit # | Front |
| Part # | Rear | Part # | Minimum | Maximum |
#51 |
| 30000449 | #40 | 20004263 | 25,000 | 35,000 | |
|
| ||||||
|
|
|
|
|
|
|
|
| Conversion to LP |
| Input (BTU/h) | |||
Kit # | Front | Part # | Rear | Part # | Minimum | Maximum | |
#57 | 20004587 | #54 | 20000130 | 27,500 | 35,000 | ||
| |||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
|
Table 2. Air Shutter Adjustment
Model | Natural Gas | LP |
RDVOD, RDVOD with |
|
|
Vermont Castings Draft Hood Z31D00 FSDHAG | 1” | Fully Closed |
|
|
|
Minimum rear injector air inlet openings.
3232 | 20004188 |