Vermont Casting RDVOD manual Wiring Diagrams, Blk

Page 32

Wiring Diagrams

Radiance Direct Vent /Natural Vent Gas Heater

OFF ON

On/Off Switch

Wiring

POWER

CORD

FAN

Black

TP/TH

TP

TH

opile Therm

Black

ST124b

WHT BLK

BLK

Chassis

GRN

 

 

Ground

 

 

 

 

 

K

 

 

L

 

 

B

 

BLK

 

 

 

 

Thermostat

Optional Thermostat

(Optional)

Wiring

 

FAN JUNCTION BOX

Black

TP/TH

TP

TH

Thermopile

Black

ST124c

Strain Relief

ON / OFF

Rheostat

Snapstat

Fig. 66 On/off switch and optional thermostat circuit.

NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP- PLIED WITH THE APPLIANCE, MUST BE RE- PLACED, IT MUST BE REPLACED WITH TYPE SF-2, 200°C WIRE OR ITS EQUIVALENT.

Draft Hood

Vent Safety Switch

TH

TP

Gas

Valve

TH

 

TP

 

 

ST359

Fig. 67 Draft Hood Adapter (FSDHAG) wiring. Used on

RN/RP models only.

 

K

WHT

 

 

L

BLK

B

 

 

 

GRN

Chassis Ground

RHEOSTAT / SNAPSTAT

 

 

BOX

ST153

MOTOR

Schematic Diagram

 

BLK

BLK

BLK

 

 

 

BLK

SNAPSTAT

WHT

WHT

GRN

RHEOSTAT

 

 

ON/OFF

 

 

ST236

Fig. 68 Fan circuit.

20004188

35

Image 32
Contents Radiance Direct Vent/Natural Vent Gas Heater Installation & Operating Instructions Radiance Direct Vent/Natural Vent Stove Dimensions Radiance dimensionsClearance Requirements Installation RequirementsLocating The Stove Hearth Requirements Wall Centerline from FloorWall and Ceiling Clearances Gas Specifications Gas Inlet and Manifold PressuresHigh Elevations Horizontal Termination Direct Vent onlyVent Termination Clearances Restictor Plate is used on Direct Vent installations onlyVertical Termination Direct Vent only Location of Vent Termination Canadian Installations US Installations General Venting Information Termination LocationVenting Requirements Natural Vent Only Plate supplied with the stove is not usedVenting Requirements and Options Direct Vent only Approved Vent System ComponentsAssembly Procedures Parts Bag ContentsTools Required Unpack and Assemble LegsInstall the Optional Fan Remove rear shroudVenting System Assembly Direct Vent General Information Install the Vent Adapter PipeFor Canadian installations The venting system must Attach the Inner Vent Assembly to the stoveDiscard the inner starter pipe shipped with the log Side Wall Termination AssemblyInstall the Outer Adapter Pipe. Orient the verti Measure the horizontal length Vertical Through the Roof Vent Assembly Vent Termination Below GradeVenting System Assembly Natural Vent General Information Install firestops and attic insulation shieldInstall the Vent Pipe Install Log SetInstall the left and right rear logs and the right log Connect the Gas Supply LineInstall ON/OFF Switch Install the Mesh and GrilleBurner Information Thermostat Connection optionalFlame & Temperature Adjustment Flame CharacteristicsOperation Your First FireLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionShut Off Procedure Transmitter Operation Off ModeOn Manual Mode Delay Timer ModeLocal Path On Path Auto Path Auto Mode Fan Override During Auto ModeChange Between F/C Temperature Units Disable Thermostat Function Air Shutter Adjustment Injector Orifice Size Matrix All Models Conversion to Natural Gas Input BTU/hMaintenance Check the Gas Flame Regularly Gasket ReplacementInspect the Vent System Annually Wiring Diagrams BLKRadiance Direct Vent/Natural Vent Gas Heater Rdvod DescriptionRadiance Direct Vent/Natural Vent Gas Heater Rdvod Fuel Conversion Kits Shell Enamel Parts Radiance Direct Vent / Natural VentOptional Accessories Limited Lifetime Warranty Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %