Vermont Casting RDVOD manual Assembly Procedures, Tools Required, Parts Bag Contents

Page 12

Radiance Direct Vent /Natural Vent Gas Heater

Assembly Procedures

WARNING

Failure to position the parts in accor- dance with these diagrams or failure to

use only parts specifically approved for use with this heater may result in property dam- age or personal injury.

This heater and components are heavy. Have help available for assembly.

Tools Required

Phillips screwdriver (stub)

power drill

utility knife

reciprocating saw

metal drill bit: size 28 (.140”/3.5mm)

Parts Bag Contents:

Control door handle/screw

(3) Vent Screws

(2) Switch bracket screws

Ceramic handle w/insert lifter (handle for operable door)

On-Off switch, housing, and wiring harness

(3)Phillips round-head bolts, 1/4”- 20 x 1/2”

(2) Bag of Lava Rocks

(1) Tube of Vent Gasket Cement

(1) Vent Restrictor Plate, 2¹⁄₄" inside diameter

Owner Registration Card

(4) CS, Hex Hd 3/8-16 x 1 Gr 2-Z

(4) Washer, Fl 3/8-Z

Unpack and Assemble Legs

The Radiance is shipped upright. Cut the shipping straps and set stove upright.

1.Slide stove to the rear of the pallet just far enough to access rear leg holes. Make sure the stove does not tip over backwards. (Fig. 12)

2.Attach the rear legs using 3/8” hex head bolts and flat washer supplied. Tighten with a 9/16” wrench or socket.

3.Carefully tip the stove onto its rear legs. Adjust the pallet to allow access to one of the front leg holes. Be sure to leave the pallet under the stove to prevent the stove from falling fully forward. (Fig. 13) CAUTION: To prevent valve tubing from being crushed or damaged, make sure to rest valve on wooden pallet.

ST720

Fig. 12 Slide stove back just far enough to access rear leg holes.

Washer

Hex Head Bolt

Fig. 13 Carefully tip stove onto back legs. Leave pallet under stove to keep stove from falling fully forward.

4.Have your assistant attach one leg using the hard- ware described.

5.Move the pallet to allow access to the other front leg hole. Attach remaining leg.

6.Remove pallet and allow stove to gently rest on all four legs.

7.Adjust leg levelers to compensate for irregularities in the hearth.

NOTE: Verify the two relief doors (located on top of the firebox) are properly seated on the gasket. The doors should sit flush on the gasket, and should lift easily from the seal around the opening.

20004188

13

Image 12
Contents Radiance Direct Vent/Natural Vent Gas Heater Installation & Operating Instructions Radiance Direct Vent/Natural Vent Stove Dimensions Radiance dimensionsInstallation Requirements Locating The StoveClearance Requirements Wall Centerline from Floor Wall and Ceiling ClearancesHearth Requirements Gas Specifications Gas Inlet and Manifold PressuresHigh Elevations Horizontal Termination Direct Vent onlyRestictor Plate is used on Direct Vent installations only Vertical Termination Direct Vent onlyVent Termination Clearances Location of Vent Termination Canadian Installations US Installations General Venting Information Termination LocationVenting Requirements Natural Vent Only Plate supplied with the stove is not usedVenting Requirements and Options Direct Vent only Approved Vent System ComponentsAssembly Procedures Parts Bag ContentsTools Required Unpack and Assemble LegsInstall the Optional Fan Remove rear shroudVenting System Assembly Direct Vent General Information Install the Vent Adapter PipeFor Canadian installations The venting system must Attach the Inner Vent Assembly to the stoveSide Wall Termination Assembly Install the Outer Adapter Pipe. Orient the vertiDiscard the inner starter pipe shipped with the log Measure the horizontal length Vertical Through the Roof Vent Assembly Vent Termination Below GradeVenting System Assembly Natural Vent General Information Install firestops and attic insulation shieldInstall the Vent Pipe Install Log SetInstall the left and right rear logs and the right log Connect the Gas Supply LineInstall ON/OFF Switch Install the Mesh and GrilleBurner Information Thermostat Connection optionalFlame & Temperature Adjustment Flame CharacteristicsOperation Your First FireLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionShut Off Procedure Transmitter Operation Off ModeOn Manual Mode Delay Timer ModeLocal Path On Path Auto Path Auto Mode Fan Override During Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionAir Shutter Adjustment Injector Orifice Size MatrixAll Models Conversion to Natural Gas Input BTU/hMaintenance Gasket Replacement Inspect the Vent System AnnuallyCheck the Gas Flame Regularly Wiring Diagrams BLKRadiance Direct Vent/Natural Vent Gas Heater Rdvod DescriptionRadiance Direct Vent/Natural Vent Gas Heater Rdvod Fuel Conversion Kits Shell Enamel Parts Radiance Direct Vent / Natural VentOptional Accessories Limited Lifetime Warranty Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %