Vermont Casting RDVOD Fan Override During Auto Mode, Change Between F/C Temperature Units

Page 28

Auto Mode

In the AUTO mode, the room temperature, set tem- perature, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons.

When the control is in the AUTO mode, the main burner will turn on/off or modulate based on the heat needed to maintain the set temperature. The flame level will change automatically to optimize the heat output needed to maintain the set temperature. To change the set temperature, press the up or down key. Pushing a key once will change the temperature by one degree.

In the AUTO mode, the fan speed will increase with increasing flame height or decrease with decreasing flame height. “AUTO” is displayed next to the flame and fan icons.

Fan Override During Auto Mode

If a lower or higher fan speed is desired when operating in the AUTO mode, the fan speed can be overridden by pushing the fan button followed by the up or down key. Pushing a key once will change the fan level by one unit. In this mode “AUTO” is displayed next to the flame icon and “MANUAL” is displayed next to the fan icon.

Change Between F/C Temperature Units

Push the up and down arrow keys simultaneously for at least 3 seconds to toggle between Fahrenheit and Celsius units.

Disable Thermostat Function

To disable the thermostat function in the AUTO mode, push the time and down keys simultaneously for at least 3 seconds.

To Change Batteries

1.Remove cover on the backside of the transmitter. Install 3 AAA batteries as shown and reattach cover.

2.Once steps 1-3 in OPERATION are completed, receiver/valve and transmitter are now ready. Press any button on transmitter for recognition process to occur between the receiver/valve and transmitter.

3.Use functions as described in TRANSMITTER sec- tion.

Troubleshooting

1.Locate LED light on valve.

2.LED will blink after every valid command received by the transmitter; this is not an error.

3.Failure codes may occur anytime after pilot burner is lit.

4.Sequence is failure code followed by light not blink- ing for 30 seconds.

Radiance Direct Vent /Natural Vent Gas Heater

 

 

Pilot As-

 

 

 

sembly

 

 

 

 

Blower

 

 

Red

FAN

 

 

 

 

Red

White

 

 

 

 

 

White

 

 

 

 

White Dots

 

 

Antenna

 

FP1038

 

 

Valve

 

 

(Bottom View)

Fig. 51 Comfort Valve wiring diagram.

5.In the event of multiple failure codes, next failure code follows previous failure code by approximately 3 seconds.

If an Error Code 3 is observed while performing the testing, complete the following:

1.Make sure the spade connectors are pushed all the way on. If rhe Error Code 3 is still showing, then go to the next step.

2.Switch the front two thermopile leads with the back two. Be sure the white lead is connected to the spade with the white dot next to it. If the Error Code 3 is still showing, replace the thermopiles.

If an Error Code 8 is observed while performing the testing, complete the following:

1.Confirm the valve is not in REMOTE mode.

If the valve is producing Error Code 8 and in RE- MOTE mode, the valve is defective and should be replaced.

If the valve is in LOCAL mode and producing Error Code 8, then go to the next step.

2.Slide the Remote/Local switch to REMOTE and teach the valve a transmitter (see item 6, page 32). The Error Code will clear itself after approximately 1.5 minutes and return to normal operation.

LED Count

Service Action

8Replace valve

7Confirm stepper motor connection exists

5 Confirm fan connection exists and works

4 Confirm gas type; jumper in place

3 Replace thermopiles

2 Turn fan ON

NOTE: Some keys are not active.

20004188

27

Image 28
Contents Radiance Direct Vent/Natural Vent Gas Heater Installation & Operating Instructions Radiance Direct Vent/Natural Vent Stove Dimensions Radiance dimensionsLocating The Stove Installation RequirementsClearance Requirements Wall and Ceiling Clearances Wall Centerline from FloorHearth Requirements Gas Specifications Gas Inlet and Manifold PressuresHigh Elevations Horizontal Termination Direct Vent onlyVertical Termination Direct Vent only Restictor Plate is used on Direct Vent installations onlyVent Termination Clearances Location of Vent Termination Canadian Installations US Installations General Venting Information Termination LocationVenting Requirements Natural Vent Only Plate supplied with the stove is not usedVenting Requirements and Options Direct Vent only Approved Vent System ComponentsAssembly Procedures Parts Bag ContentsTools Required Unpack and Assemble LegsInstall the Optional Fan Remove rear shroudVenting System Assembly Direct Vent General Information Install the Vent Adapter PipeFor Canadian installations The venting system must Attach the Inner Vent Assembly to the stoveInstall the Outer Adapter Pipe. Orient the verti Side Wall Termination AssemblyDiscard the inner starter pipe shipped with the log Measure the horizontal length Vertical Through the Roof Vent Assembly Vent Termination Below GradeVenting System Assembly Natural Vent General Information Install firestops and attic insulation shieldInstall the Vent Pipe Install Log SetInstall the left and right rear logs and the right log Connect the Gas Supply LineInstall ON/OFF Switch Install the Mesh and GrilleBurner Information Thermostat Connection optionalFlame & Temperature Adjustment Flame CharacteristicsOperation Your First FireLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionShut Off Procedure Transmitter Operation Off ModeOn Manual Mode Delay Timer ModeLocal Path On Path Auto Path Auto Mode Fan Override During Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionAir Shutter Adjustment Injector Orifice Size MatrixAll Models Conversion to Natural Gas Input BTU/hMaintenance Inspect the Vent System Annually Gasket ReplacementCheck the Gas Flame Regularly Wiring Diagrams BLKRadiance Direct Vent/Natural Vent Gas Heater Rdvod DescriptionRadiance Direct Vent/Natural Vent Gas Heater Rdvod Fuel Conversion Kits Shell Enamel Parts Radiance Direct Vent / Natural VentOptional Accessories Limited Lifetime Warranty Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %