Teledyne 6750 Options, Typical Applications, Intended Use of the Analyzer, Introduction Model

Page 14

Introduction

Model 6750

 

 

RS-232C and RS-485 outputs

Separate electronics and liquid compartments

1.2Options

The following options are available for the Model 6750 TOC Analyzer and are described in Appendix A.3:

Correlated BOD/COD

Dual NDIR Analyzers

Benchmark/Auto Validation

Auto-Cal/Auto-Clean

Automatic Multi-Range

Multi-Stream Analysis

DBPR Drinking Water

1.3Typical Applications

With excellent TOC accuracy from low parts-per-million to high concentration levels of salt-free samples, the Model 6750 is used in a variety of applications including:

 

Boiler Feedwater

Standard Method 5310 C/D

Cooling Water

EPA 415.1

Drinking Water

EPA 9060

Wastewater (limited)

ASTM D 4839-88

River Water

ASTM D 4779-88

Oil in Water

1.4 Intended Use of the Analyzer

The Analyzer is exclusively designed for monitoring of Total Organic Carbon (TOC) in water. This intended use involves carefully following the instructions provided in this manual and observing all indicated warnings, hints and instructions.

Teledyne Analytical Instruments

2

Image 14
Contents Model Teledyne Analytical InstrumentsModel Copyright 2005 Teledyne Instruments/ Analytical InstrumentsSpecific Model Information Total Organic Carbon AnalyzerSafety Messages Total Organic Carbon Analyzer Table of Contents Setup and Operation MaintenanceAppendix Index Teledyne Analytical InstrumentsList of Figures Model 6750 TOC Analyzer Front door removedDC Power Supply Module List of Tables Combustible GAS Usage Total Organic Carbon Analyzer Introduction Main Features of the AnalyzerIntroduction Intended Use of the Analyzer OptionsTypical Applications Introduction ModelOperator Interface Model 6750 TOC Analyzer Front door removedIntroduction Model Teledyne Analytical Instruments Background Theory of OperationOverview Total Organic Carbon Analyzer Theory of OperationTheory of Operation Model Npoc or TOC Direct MethodConclusion TOC Measurement Basics UV/Heated Persulfate Method of Analysis Comparison of TOC Measurement Technologies Subsystems Principles of Operation Sample HandlingSample Handling for TOC -Direct Sample Handling TOC-True TOC analysis in a continuous, on-line TOC analyzer Inorganic Carbon Removal/AnalysisRelationship Between TIC and pH OxidationOxidation Reactions Ndir CO2 Gas Detection 10 Model 6750 Ndir UnitElectronic Signal Processing, Display and Control BENCHMARK/AUTO-VALIDATION Theory of Operation Model Teledyne Analytical Instruments Unpacking the Analyzer InstallationTotal Organic Carbon Analyzer Installation Mounting the AnalyzerInstallation Model Analyzer DimensionsPower Connection Electrical ConnectionsAnalog Outputs Electrical Connections to the Model4 RS-232 Serial Connection Alarm ConnectionsGas/liquid Connections Liquid ConnectionsGas and Liquid Connections to the Analyzer Gas ConnectionsChecking the System Gas Carrier ConnectionsInstallation Model Teledyne Analytical Instruments Analyzer Startup Setup and OperationTotal Organic Carbon Analyzer Setup and Operation Setup and Operation Model Drain ConnectionsRun Mode MenusParameter Menu Alarm Settings Stream Sequencer 5 D/DBPR Detailed Calibration Procedures Methanol 100 mg/Liter 1000 mg/LiterEthylene Glycol EthanolPreparation of Phosphoric Acid Solution Total Organic Carbon Analyzer Setup and Operation Operation RUN ScreenShutdown Historical DataSetup and Operation Model Total Organic Carbon Analyzer Maintenance MaintenanceCompupter-aided Testing Troubleshooting Maintenance ModelModule Service Ndir Gas CalibrationIR Calibration Installing Calibration Adapter Ndir ServiceRemoving the Ndir Unit P/N ST36000 Total Organic Carbon Analyzer Maintenance Maintenance Model To Reassemble Use alternate tightening sequence Master Interface Board P/N ST13042-1 Removing the Master Interface Board4 D. C. Power Supply DC Power Supply ModuleCE Computer P/N Replacing CE ComputerUV Lamp Replacement UV Lamp P/N ST20009UV Reactor Assembly P/N ST20003-1 Removing the UV Reactor AssemblyUV Power Supply 10 Removing the UV Power Supply Mass Flow Controller P/N ST18001A11 Mass Flow Controller Metering Valve P/N ST1605012 Metering Valve Sparger P/N ST2002513 Sparger Pumps Maintenance Model 14 Removing the Pump Maintenance Model 13 4-20 mA Adjustment Procedure System DiagnosticsSetting 100 MV Control Voltage Total Organic Carbon Analyzer Appendix 1SpecificationsAppendix Appendix Model Sample requirementsParts Listing Description ImageAppendix Model Total Organic Carbon Analyzer Appendix Appendix Model Total Organic Carbon Analyzer Appendix Option Auto CALTrue Dual Range Option not an electronic scaling Dbpr OptionAppendix Model AS-BUILT Drawings Appendix Model Teledyne Analytical Instruments Index Total Organic Carbon Analyzer IndexIndex Model ModbusPump mounting screw Index Model