Teledyne 6750 operating instructions Pump mounting screw

Page 95

Total Organic Carbon Analyzer

Index

 

 

parameters menu, 32 parts listing, 71 persulfate, 15, 16, 19 persulfate line, 30 pH, 6, 11, 14 phosphoric acid, 38 POC, 5, 7

potassium hydrogen phthalate, 36 power connection, 23

power requirement, 70 power supply, 23

preferred method of analysis, 6 pressure swing absorption, 13 pump, 11, 63

pump head, 44, 63

pump mounting screw, 65

pump tubing, 66

purgeable organic carbon. See POC range, 69

range change, 77 reactor body, 15 reagent, 11, 70 reagent preparation, 37 reference detector, 18 relay, 25 repeatability, 69 response time, 69 rotor, 65

RS-232, 2, 18, 25, 69 run mode, 30 RUN screen, 40 RUN Screen, 31 safety information, iv sample cell, 17 sample connection, 26 sample system, 11, 12 sample temperature, 16 sapphire, 18 sapphire optics, 17 sapphire window, 51 scale, 41

serial communication, 25 serial number, iii setup, 29

shutdown, 41 signal detection, 18 signal processing, 11 sodium carbonate, 36 sodium persulfate, 37

SPAN, 39, 47 span fluid, 39 span solution, 19 sparger, 6, 9, 11, 14, 16, 61 sparger cleaning, 62 sparger flow rate, 14 sparger replacement, 62 specifications, 69 stability, 69

standard solution, 36 subsystem, 11 suspended solids, 70 synchronous, 18 system checklist, 27

SYSTEM DIAGNOSTICS, 43, 67 tables listing, xi

TC, 1, 5, 69

TC-TIC subtraction methods, 7 technician symbol, iv temperature, 69 temperature sensor, 15 TEST, 43, 67

TIC, 5, 7, 9, 11 TIC-pH relationship, 15 TOC, 12, 69

TOC analysis, 5 TOC Analyzer, 3

TOC measurememt basics, 7 TOC measurement comparison, 10 TOC SCALE, 41

TOC- True, 6 TOC value, 32 TOC-Direct, 6, 9, 12 TOC-True, 1, 7, 9, 11, 14 total carbon. See TC

total inorganic carbon. See TIC touch screen, 12 troubleshooting, 44

tubing leak, 44 tubing leaks, 60

universal power supply. See power supply

U-tube, 30 UV lamp, 15

UV lamp replacement, 56 UV power supply, 58 UV reactor, 9, 15, 16 UV reactor assembly, 57 UV reactor cleaning, 58

Teledyne Analytical Instruments

83

Image 95
Contents Teledyne Analytical Instruments ModelCopyright 2005 Teledyne Instruments/ Analytical Instruments ModelTotal Organic Carbon Analyzer Specific Model InformationSafety Messages Total Organic Carbon Analyzer Table of Contents Maintenance Setup and OperationIndex Teledyne Analytical Instruments AppendixModel 6750 TOC Analyzer Front door removed List of FiguresDC Power Supply Module List of Tables Combustible GAS Usage Total Organic Carbon Analyzer Introduction Main Features of the AnalyzerIntroduction Introduction Model OptionsTypical Applications Intended Use of the AnalyzerModel 6750 TOC Analyzer Front door removed Operator InterfaceIntroduction Model Teledyne Analytical Instruments Total Organic Carbon Analyzer Theory of Operation Theory of OperationOverview BackgroundNpoc or TOC Direct Method Theory of Operation ModelConclusion TOC Measurement Basics UV/Heated Persulfate Method of Analysis Comparison of TOC Measurement Technologies Sample Handling Subsystems Principles of OperationSample Handling for TOC -Direct Sample Handling TOC-True Inorganic Carbon Removal/Analysis TOC analysis in a continuous, on-line TOC analyzerOxidation Relationship Between TIC and pHOxidation Reactions 10 Model 6750 Ndir Unit Ndir CO2 Gas DetectionElectronic Signal Processing, Display and Control BENCHMARK/AUTO-VALIDATION Theory of Operation Model Teledyne Analytical Instruments Mounting the Analyzer InstallationTotal Organic Carbon Analyzer Installation Unpacking the AnalyzerAnalyzer Dimensions Installation ModelElectrical Connections Power ConnectionElectrical Connections to the Model Analog OutputsLiquid Connections Alarm ConnectionsGas/liquid Connections 4 RS-232 Serial ConnectionGas Connections Gas and Liquid Connections to the AnalyzerGas Carrier Connections Checking the SystemInstallation Model Teledyne Analytical Instruments Analyzer Startup Setup and OperationTotal Organic Carbon Analyzer Setup and Operation Drain Connections Setup and Operation ModelMenus Run ModeParameter Menu Alarm Settings Stream Sequencer 5 D/DBPR Detailed Calibration Procedures Ethanol 100 mg/Liter 1000 mg/LiterEthylene Glycol MethanolPreparation of Phosphoric Acid Solution Total Organic Carbon Analyzer Setup and Operation RUN Screen OperationHistorical Data ShutdownSetup and Operation Model Total Organic Carbon Analyzer Maintenance MaintenanceCompupter-aided Testing Maintenance Model TroubleshootingNdir Gas Calibration Module ServiceIR Calibration Ndir Service Installing Calibration AdapterRemoving the Ndir Unit P/N ST36000 Total Organic Carbon Analyzer Maintenance Maintenance Model To Reassemble Use alternate tightening sequence Removing the Master Interface Board Master Interface Board P/N ST13042-1DC Power Supply Module 4 D. C. Power SupplyReplacing CE Computer CE Computer P/NUV Lamp P/N ST20009 UV Lamp ReplacementRemoving the UV Reactor Assembly UV Reactor Assembly P/N ST20003-1UV Power Supply Mass Flow Controller P/N ST18001A 10 Removing the UV Power SupplyMetering Valve P/N ST16050 11 Mass Flow ControllerSparger P/N ST20025 12 Metering Valve13 Sparger Pumps Maintenance Model 14 Removing the Pump Maintenance Model System Diagnostics 13 4-20 mA Adjustment ProcedureSetting 100 MV Control Voltage Total Organic Carbon Analyzer Appendix 1SpecificationsAppendix Sample requirements Appendix ModelDescription Image Parts ListingAppendix Model Total Organic Carbon Analyzer Appendix Appendix Model Total Organic Carbon Analyzer Appendix Auto CAL OptionDbpr Option True Dual Range Option not an electronic scalingAppendix Model AS-BUILT Drawings Appendix Model Teledyne Analytical Instruments Total Organic Carbon Analyzer Index IndexModbus Index ModelPump mounting screw Index Model