Heat & Glo LifeStyle SUPREME-N-I30AU, SUPREME-P-I30AU Design and Installation Considerations

Page 17

B. Design and Installation Considerations

Heat & Glo gas inserts are designed for installations into solid fuel masonry or factory built fireplaces that have been installed in accordance with the National, Provin- cial, State and local building codes. Fireplaces are to be constructed of non-combustible materials and, in the ab- sence of local or regional codes, meet criteria of NFPA 211. No additional outside air source is required.

Installation MUST comply with local, regional, state and na- tional codes and regulations. Consult insurance carrier, local building inspector, fire officials or authorities having jurisdic- tion over restrictions, installation inspection and permits.

Prior to installing the gas insert:

Have the chimney and adjacent structure inspected and cleaned by qualified professionals. Hearth & Home Technologies recommends that NFI or CSIA certified professionals, or technicians under the direction of certi- fied professionals, conduct a minimum of a NFPA 211 Level 2 inspection of the chimney.

Replace component parts of the chimney and fireplace as specified by the professionals.

Ensure combustible mantel and surround clearances comply with applicable codes and regulations for solid- fuel fireplaces. In the absence of local or regional codes, refer to NFPA 211.

Ensure all joints are properly engaged and the chimney is properly secured.

Minimum fireplace size. See Section 5.A.

Gas supply piping requirements.

Electrical wiring requirements.

Finishing details.

Whether optional accessories—devices such as a wall switch or remote control—are desired.

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified technician, service agency or your dealer.

C. Tools and Supplies Needed

Before beginning the installation be sure that the following tools and building supplies are available.

Tape measure

Framing material

Pliers

Non-corrosive leak check solution

Hammer

Phillips screwdriver

Gloves

Framing square

Voltmeter

Electric drill and bits -1/4 in. (6 mm)

Plumb line

Safety glasses

Level

Reciprocating saw

Manometer

Flat blade screwdriver

1/2 - 3/4 in. (13 - 18 mm) length, #6 or #8 Self-drilling screws

Caulking material 149 °C (300 °F) minimum continuous exposure rating)

Caulking material 649 °C (1200 °F) or higher minimum continuous exposure rating)

D. Inspect Appliance and Components

Carefully remove the appliance and components from the packaging.

The vent system components and decorative doors and fronts may be shipped in separate packages.

If packaged separately, the log set and appliance grate must be installed.

Report to your dealer any parts damaged in shipment, particularly the condition of the glass.

Read all of the instructions before starting the instal- lation. Follow these instructions carefully during the installation to ensure maximum safety and benefit.

WARNING! Risk of Fire or Explosion! Damaged parts could impair safe operation. DO NOT install damaged, in- complete or substitute components. Keep appliance dry.

Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:

Installation and use of any damaged appliance or vent system component.

Modification of the appliance or vent system.

Installation other than as instructed by Hearth & Home Technologies.

Improper positioning of the gas logs or the glass door.

Installation and/or use of any component part not approved by Hearth & Home Technologies.

Any such action may cause a fire hazard.

WARNING! Risk of Fire/Explosion/Electric Shock! DO NOT use this appliance if any part has been under water. Call a qualified technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water.

Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU2222-900 Rev. P • 6/12

17

Image 17
Contents SAI Global Ref No GSCS20181 Models SUPREME-N-I30AU SUPREME-P-I30AUWhat to do if you smell gas HOT SurfacesMODELSSupreme-N-I30AU,Supreme-P-I30AU Homeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Australian Warranty InformationOther Rights Perth Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyIPI Battery Tray/Battery Installation Clear SpaceBefore Lighting Fireplace Module ResetNine Hour Safety Shutdown Feature Final inspection by Lighting Instructions IPIWhat to do if YOU Smell GAS GAS ValveAfter Appliance is Lit Frequently Asked QuestionsIssue Solutions Maintenance and Service Gasket Seal and Glass Assembly Inspection Maintenance Tasks-Service TechnicianLogs FireboxTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Minimum Fireplace Opening Fireplace Size RequirementsFireplace Opening TOP View Front View Side ViewSUPREME-I30AU Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVent Limits Venting ComponentsPage Placing, Securing and Leveling Appliance Masonry Installing Adaptor and Termination CapFactory Built Damper Flashing Kit OptionalModel Flue Termination Approval Vent Kits Components Direct Vent Flex Liner Accessory KitsHeat Shield Requirements for Horizontal Termination For Horizontal Terminations using the SLP-TRAP2Flue Termination Must adhere to pipe clearances Colinear to Coaxial Adapter Must adhere to pipe clearances Minimum construction requirements Alternate built-in optionsMinimum Total SLP-TVHWLink Adapter Maximum TotalNON-COMBUSTIBLE Base Under Unit Flue Starter Plate Gas Connection Gas InformationElectrical Information Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Fan Wiring Diagram Optional Accessories RequirementsInstallation Precautions Kit ContentsREM300-HNG-AU Instructions Fireplace Specific InformationInstallation of Remote Control Housing Changing Temperature ScaleProgramming the RC300AU to the Control Module AUX300CE Module InstallationFan Installation Standby mode Idle When Remote is in on ModeDisplay Screen Function ButtonsAbout OFF Mode About on ModeAdjusting Flame Height Adjusting Fan SpeedAdjusting Timer Adjusting ThermostatSetting the Child Lock Power OutageSymptom Possible Cause Corrective Action Frequently Asked Questions/TroubleshootingClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Pilot AS Sembly LOG PIN Grate Tines Install the Log AssemblyFor LOG #6 Corner LOG Flush With LOG TABLatches Air Shutter SettingAir Shutter Settings Decorative Fronts and Surrounds Required to Complete Insert InstallationIPI+ Optional AccessoriesOptional RC300AU Remote Optional BRICK-SI30 Kit IntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action If the pilot continues Inspect Maintenance Tasks Maintenance TasksModel Dimensions Appliance Dimension DiagramReference Materials SUPREME-I30-AULog Set Assembly Service PartsMetal Insert, IPI Description Comments Part Number#15 Valve Assembly SUPREME-N-I30AU, SUPREME-P-I30AU Contact Information

SUPREME-P-I30AU, SUPREME-N-I30AU specifications

The Heat & Glo LifeStyle SUPREME-P-I30AU and SUPREME-N-I30AU are premium gas fireplaces designed to create a cozy, inviting atmosphere while offering modern technological features and exceptional performance. These units are perfect additions to any home, blending elegance with practicality.

One of the standout features of the SUPREME series is its versatile design. The fireplaces are available in both linear and traditional styles, allowing homeowners to choose the configuration that best complements their living space. With a sleek, modern aesthetic, the SUPREME-P-I30AU offers a panoramic view of the flames, making it a captivating focal point in any room.

These models are equipped with advanced heating capabilities. The powerful heat output ensures that the fireplace can effectively warm spaces ranging from medium to large. Homeowners can enjoy optimal comfort during the colder months, knowing they have a reliable source of heat at their disposal.

Another key characteristic is the innovative IntelliFire technology, which automates the ignition system and monitors the flame to ensure safe and efficient operation. This feature not only enhances the user experience but also minimizes energy consumption by allowing the unit to alternate between different flame settings based on the home's heating needs.

Installation is made easy with the SUPREME series, thanks to its flexible venting options. The fireplaces can be vented either vertically or horizontally, making them suitable for various home layouts. Additionally, the units are designed for easy access to components, simplifying maintenance and ensuring longevity.

Both the SUPREME-P-I30AU and SUPREME-N-I30AU come with a range of aesthetic options for customization, including different media choices such as logs, glass, and stones. This allows users to tailor the appearance of their fireplace to match their personal style and home décor.

Safety features are paramount in the design of the SUPREME series. The fireplaces include advanced safety controls and thermal sensors to prevent overheating and ensure peace of mind for users.

In summary, the Heat & Glo LifeStyle SUPREME-P-I30AU and SUPREME-N-I30AU stand out due to their stylish designs, powerful heating capabilities, innovative technologies, and customizable options, making them ideal choices for anyone looking to enhance their home with a functional and aesthetically pleasing gas fireplace.