Heat & Glo LifeStyle SUPREME-N-I30AU, SUPREME-P-I30AU owner manual Inspect Maintenance Tasks

Page 55

B. Maintenance Tasks

Inspect

 

Maintenance Tasks

 

 

Doors

1. Inspect for scratches, dents or other damage and repair as necessary.

 

 

 

 

2.

Verify no obstructions to airflow.

 

 

 

 

3.

Verify maintenance of proper clearance to combustible household objects.

 

 

Gasket Seal, Glass

1. Inspect gasket seal and its condition.

Assembly and Glass

 

 

2.

Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat.

 

 

 

 

 

3.

Confirm there is no damage to glass or glass frame. Replace as necessary.

 

 

 

4. Verify that latches engage properly, clip studs are not stripped, and glass attachment components are intact

 

 

and operating properly. Replace as necessary.

 

 

 

 

5.

Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be removed.

 

 

Valve Compartment

1. Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw tips

and Firebox Top

 

that have penetrated the sheet metal are sharp and should be avoided.

 

2.

Remove any foreign objects.

 

 

 

 

3.

Verify unobstructed air circulation.

 

 

Logs

1. Inspect for broken, damaged, or missing logs. Replace as necessary.

 

 

 

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as necessary.

 

 

Firebox

1. Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as necessary.

 

 

 

 

2.

Replace appliance if firebox has been perforated.

 

 

Burner Ignition and

1. Verify burner is properly secured and aligned with pilot or igniter.

Operation

 

 

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary.

 

 

 

 

 

3.

Replace ember materials with new dime-size and shape pieces. Do not block ports or obstruct lighting paths.

 

 

 

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

 

 

 

5.

Inspect for lifting or other flame problems.

 

 

 

 

6.

Inspect orifice for soot, dirt or corrosion.

 

 

 

 

7.

Verify manifold and inlet pressures. Adjust regulator as required.

 

 

 

 

8.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

 

 

 

9.

Inspect thermocouple/thermopile or IPI sensor rod for soot, corrosion and deterioration. Polish with fine steel

 

 

wool or replace as required.

Flueing

1. Inspect venting for blockage or obstruction such as bird nests, leaves, etc.

 

 

 

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

 

 

 

3.

Verify that termination cap clearance to subsequent construction (building additions, decks, fences or sheds)

 

 

has been maintained.

 

 

 

 

4.

Inspect for corrosion or separation.

 

 

 

 

5.

Verify weather stripping, sealing and flashing remains intact.

 

 

Remote controls

1. Verify operation of remote.

 

 

 

 

2.

Replace batteries in remote transmitters and battery-powered receivers.

 

 

Carbon Deposition

1. Appliances incorporating a live fuel effect, and designed to operate with luminous flames, may exhibit slight

 

 

carbon deposition.

 

 

 

Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU2222-900 Rev. P • 6/12

55

Image 55
Contents HOT Surfaces Models SUPREME-N-I30AU SUPREME-P-I30AUSAI Global Ref No GSCS20181 What to do if you smell gasMODELSSupreme-N-I30AU,Supreme-P-I30AU Homeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Australian Warranty InformationOther Rights Perth Listing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches IPI Battery Tray/Battery InstallationNine Hour Safety Shutdown Feature Module ResetBefore Lighting Fireplace GAS Valve Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASIssue Solutions Frequently Asked QuestionsAfter Appliance is Lit Maintenance and Service Firebox Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection LogsTypical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Minimum Fireplace Opening Fireplace Size RequirementsFireplace Opening TOP View Front View Side ViewSUPREME-I30AU Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceConnecting Vent Pipe Vent LimitsPage Placing, Securing and Leveling Appliance Damper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory BuiltModel Flue Termination Approval Vent Kits Components Direct Vent Flex Liner Accessory KitsFlue Termination For Horizontal Terminations using the SLP-TRAP2Heat Shield Requirements for Horizontal Termination Must adhere to pipe clearances Colinear to Coaxial Adapter Must adhere to pipe clearances Minimum construction requirements Alternate built-in optionsMaximum Total SLP-TVHWMinimum Total Link AdapterNON-COMBUSTIBLE Base Under Unit Flue Starter Plate Gas Connection Gas InformationIntelliFire PlusTM Ignition System Wiring Wiring RequirementsElectrical Information Fan Wiring Diagram Optional Accessories RequirementsFireplace Specific Information Kit ContentsInstallation Precautions REM300-HNG-AU InstructionsInstallation of Remote Control Housing Changing Temperature ScaleFan Installation AUX300CE Module InstallationProgramming the RC300AU to the Control Module Function Buttons Idle When Remote is in on ModeStandby mode Display ScreenAdjusting Fan Speed About on ModeAbout OFF Mode Adjusting Flame HeightPower Outage Adjusting ThermostatAdjusting Timer Setting the Child LockSymptom Possible Cause Corrective Action Frequently Asked Questions/TroubleshootingClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Pilot AS Sembly LOG PIN Grate Tines Install the Log AssemblyFor LOG #6 Corner LOG Flush With LOG TABAir Shutter Settings Air Shutter SettingLatches Decorative Fronts and Surrounds Required to Complete Insert InstallationOptional RC300AU Remote Optional BRICK-SI30 Kit Optional AccessoriesIPI+ Symptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System If the pilot continues Inspect Maintenance Tasks Maintenance TasksSUPREME-I30-AU Appliance Dimension DiagramModel Dimensions Reference MaterialsDescription Comments Part Number Service PartsLog Set Assembly Metal Insert, IPI#15 Valve Assembly SUPREME-N-I30AU, SUPREME-P-I30AU Contact Information

SUPREME-P-I30AU, SUPREME-N-I30AU specifications

The Heat & Glo LifeStyle SUPREME-P-I30AU and SUPREME-N-I30AU are premium gas fireplaces designed to create a cozy, inviting atmosphere while offering modern technological features and exceptional performance. These units are perfect additions to any home, blending elegance with practicality.

One of the standout features of the SUPREME series is its versatile design. The fireplaces are available in both linear and traditional styles, allowing homeowners to choose the configuration that best complements their living space. With a sleek, modern aesthetic, the SUPREME-P-I30AU offers a panoramic view of the flames, making it a captivating focal point in any room.

These models are equipped with advanced heating capabilities. The powerful heat output ensures that the fireplace can effectively warm spaces ranging from medium to large. Homeowners can enjoy optimal comfort during the colder months, knowing they have a reliable source of heat at their disposal.

Another key characteristic is the innovative IntelliFire technology, which automates the ignition system and monitors the flame to ensure safe and efficient operation. This feature not only enhances the user experience but also minimizes energy consumption by allowing the unit to alternate between different flame settings based on the home's heating needs.

Installation is made easy with the SUPREME series, thanks to its flexible venting options. The fireplaces can be vented either vertically or horizontally, making them suitable for various home layouts. Additionally, the units are designed for easy access to components, simplifying maintenance and ensuring longevity.

Both the SUPREME-P-I30AU and SUPREME-N-I30AU come with a range of aesthetic options for customization, including different media choices such as logs, glass, and stones. This allows users to tailor the appearance of their fireplace to match their personal style and home décor.

Safety features are paramount in the design of the SUPREME series. The fireplaces include advanced safety controls and thermal sensors to prevent overheating and ensure peace of mind for users.

In summary, the Heat & Glo LifeStyle SUPREME-P-I30AU and SUPREME-N-I30AU stand out due to their stylish designs, powerful heating capabilities, innovative technologies, and customizable options, making them ideal choices for anyone looking to enhance their home with a functional and aesthetically pleasing gas fireplace.