Heat & Glo LifeStyle SUPREME-N-I30AU Service Parts, Log Set Assembly, Metal Insert, IPI

Page 57

B. Service Parts

SUPREME-N-I30AU, SUPREME-P-I30AU

30” Metal Insert, IPI

Beginning Manufacturing Date: Feb 2011

 

Ending Manufacturing Date: ______

Log Set Assembly

 

 

6

5

7

3

 

4

2

1

 

 

 

8

 

 

 

 

 

 

9

 

 

 

10

 

 

 

14

 

 

 

13

 

 

 

12

 

 

 

11

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

 

Log Assembly

 

LOGS-I30AU

1

Log 1

 

SRV2222-701

2

Log 2

 

SRV2222-705

3

Log 3

 

SRV2222-702

4

Log 4

 

SRV2222-704

5

Log 5

 

SRV2222-703

6

Log 6

 

SRV2222-706

7

Termination Plate Assembly

 

2206-012

 

Flex Pipe Handle

 

438-351

 

Gasket

 

2206-401

8

Burner Assembly

 

2206-009

9

Base Pan

 

2206-106

10

Grate Assemby

 

2206-016

11

Glass Door Assembly

 

GLA-2206

12

Control Panel

 

2222-129

13

Power Cord Assembly

 

2222-374

14

Blower Assembly

 

GFK210-240V

Additional service part numbers appear on following page.

Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU2222-900 Rev. P • 6/12

57

Image 57
Contents SAI Global Ref No GSCS20181 Models SUPREME-N-I30AU SUPREME-P-I30AUWhat to do if you smell gas HOT SurfacesMODELSSupreme-N-I30AU,Supreme-P-I30AU Homeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Australian Warranty InformationOther Rights Perth Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyIPI Battery Tray/Battery Installation Clear SpaceModule Reset Nine Hour Safety Shutdown FeatureBefore Lighting Fireplace Final inspection by Lighting Instructions IPIWhat to do if YOU Smell GAS GAS ValveFrequently Asked Questions Issue SolutionsAfter Appliance is Lit Maintenance and Service Gasket Seal and Glass Assembly Inspection Maintenance Tasks-Service TechnicianLogs FireboxTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Minimum Fireplace Opening Fireplace Size RequirementsFireplace Opening TOP View Front View Side ViewSUPREME-I30AU Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVent Limits Venting ComponentsPage Placing, Securing and Leveling Appliance Masonry Installing Adaptor and Termination CapFactory Built Damper Flashing Kit OptionalModel Flue Termination Approval Vent Kits Components Direct Vent Flex Liner Accessory KitsFor Horizontal Terminations using the SLP-TRAP2 Flue TerminationHeat Shield Requirements for Horizontal Termination Must adhere to pipe clearances Colinear to Coaxial Adapter Must adhere to pipe clearances Minimum construction requirements Alternate built-in optionsMinimum Total SLP-TVHWLink Adapter Maximum TotalNON-COMBUSTIBLE Base Under Unit Flue Starter Plate Gas Connection Gas InformationWiring Requirements IntelliFire PlusTM Ignition System WiringElectrical Information Fan Wiring Diagram Optional Accessories RequirementsInstallation Precautions Kit ContentsREM300-HNG-AU Instructions Fireplace Specific InformationInstallation of Remote Control Housing Changing Temperature ScaleAUX300CE Module Installation Fan InstallationProgramming the RC300AU to the Control Module Standby mode Idle When Remote is in on ModeDisplay Screen Function ButtonsAbout OFF Mode About on ModeAdjusting Flame Height Adjusting Fan SpeedAdjusting Timer Adjusting ThermostatSetting the Child Lock Power OutageSymptom Possible Cause Corrective Action Frequently Asked Questions/TroubleshootingClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Pilot AS Sembly LOG PIN Grate Tines Install the Log AssemblyFor LOG #6 Corner LOG Flush With LOG TABAir Shutter Setting Air Shutter SettingsLatches Decorative Fronts and Surrounds Required to Complete Insert InstallationOptional Accessories Optional RC300AU Remote Optional BRICK-SI30 KitIPI+ Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Plus Ignition System If the pilot continues Inspect Maintenance Tasks Maintenance TasksModel Dimensions Appliance Dimension DiagramReference Materials SUPREME-I30-AULog Set Assembly Service PartsMetal Insert, IPI Description Comments Part Number#15 Valve Assembly SUPREME-N-I30AU, SUPREME-P-I30AU Contact Information

SUPREME-P-I30AU, SUPREME-N-I30AU specifications

The Heat & Glo LifeStyle SUPREME-P-I30AU and SUPREME-N-I30AU are premium gas fireplaces designed to create a cozy, inviting atmosphere while offering modern technological features and exceptional performance. These units are perfect additions to any home, blending elegance with practicality.

One of the standout features of the SUPREME series is its versatile design. The fireplaces are available in both linear and traditional styles, allowing homeowners to choose the configuration that best complements their living space. With a sleek, modern aesthetic, the SUPREME-P-I30AU offers a panoramic view of the flames, making it a captivating focal point in any room.

These models are equipped with advanced heating capabilities. The powerful heat output ensures that the fireplace can effectively warm spaces ranging from medium to large. Homeowners can enjoy optimal comfort during the colder months, knowing they have a reliable source of heat at their disposal.

Another key characteristic is the innovative IntelliFire technology, which automates the ignition system and monitors the flame to ensure safe and efficient operation. This feature not only enhances the user experience but also minimizes energy consumption by allowing the unit to alternate between different flame settings based on the home's heating needs.

Installation is made easy with the SUPREME series, thanks to its flexible venting options. The fireplaces can be vented either vertically or horizontally, making them suitable for various home layouts. Additionally, the units are designed for easy access to components, simplifying maintenance and ensuring longevity.

Both the SUPREME-P-I30AU and SUPREME-N-I30AU come with a range of aesthetic options for customization, including different media choices such as logs, glass, and stones. This allows users to tailor the appearance of their fireplace to match their personal style and home décor.

Safety features are paramount in the design of the SUPREME series. The fireplaces include advanced safety controls and thermal sensors to prevent overheating and ensure peace of mind for users.

In summary, the Heat & Glo LifeStyle SUPREME-P-I30AU and SUPREME-N-I30AU stand out due to their stylish designs, powerful heating capabilities, innovative technologies, and customizable options, making them ideal choices for anyone looking to enhance their home with a functional and aesthetically pleasing gas fireplace.