Heat & Glo LifeStyle SUPREME-P-I30AU, SUPREME-N-I30AU owner manual #15 Valve Assembly

Page 58

B. Service Parts

SUPREME-N-I30AU, SUPREME-P-I30AU

Beginning Manufacturing Date: Feb 2011

Ending Manufacturing Date: ______

 

#15 Valve Assembly

 

15.4

15.3

 

 

15.5

 

 

 

 

 

 

15.2

 

 

 

 

15.1

 

 

15.6

 

 

 

 

15.7

 

 

 

 

15.9

 

 

 

 

 

15.8

15.17

 

 

 

 

 

 

15.10

 

 

 

 

15.11

15.12

15.16

 

 

 

 

 

 

15.13

15.15

 

 

 

 

15.14

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

15.1

3-Hole Grommet

 

2118-420

15.2

Pilot Bracket

Pre June 2012

2206-105

 

 

Post June 2012

2206-120

 

 

 

 

 

 

 

Pilot Assembly N

Pre June 2012

2198-014

15.3

Post June 2012

2202-013

 

 

 

 

Pilot Assembly P

Pre June 2012

2198-015

 

 

Post June 2012

2202-014

 

 

 

 

 

 

15.4

Orifice N (#36C)

 

582-836

 

 

 

Orifice P (#52C)

 

582-852

 

 

15.5

18” Flex Tube Assembly

 

530-302A

15.6

Control Panel Bracket

 

2205-128

15.7

Valve Bracket

 

2205-146

 

 

 

 

15.8

Module

 

2166-306

15.9

Flex Ball Valve Assembly

 

2098-320A

15.10

Valve N

 

2166-302

 

 

 

Valve P

 

2166-303

 

 

15.11

Brass Connector

Pkg of 5

303-315/5

15.12

Power Supply Adapter

 

2166-305

15.13

Wire Harness

 

2166-304

15.14

Jumper Wire, Remote

 

2103-013

15.15

Jumper Wire

 

2187-198

15.16

Battery Pack**

 

4067-223

15.17

Aux300 CE

 

2166-340

**Fuse for battery pack can be sourced locally, not a warranty item. Specs are 500mA~10A 3/4” long Additional service part numbers appear on following page.

58

Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU2222-900 Rev. P • 6/12

Image 58
Contents What to do if you smell gas Models SUPREME-N-I30AU SUPREME-P-I30AUSAI Global Ref No GSCS20181 HOT SurfacesMODELSSupreme-N-I30AU,Supreme-P-I30AU Congratulations Homeowner Reference InformationTable of Contents User GuideAustralian Warranty Information Limited Lifetime WarrantyOther Rights Perth Listing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace IPI Battery Tray/Battery Installation Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceNine Hour Safety Shutdown Feature Module ResetBefore Lighting Fireplace What to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveIssue Solutions Frequently Asked QuestionsAfter Appliance is Lit Maintenance and Service Logs Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection FireboxGetting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Fireplace Size Requirements Minimum Fireplace OpeningTOP View Front View Side View Fireplace OpeningMantel and Wall Projections SUPREME-I30AUTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Vent Limits Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsPage Placing, Securing and Leveling Appliance Factory Built Installing Adaptor and Termination CapMasonry Damper Flashing Kit OptionalModel Flue Termination Approval Direct Vent Flex Liner Accessory Kits Vent Kits ComponentsFlue Termination For Horizontal Terminations using the SLP-TRAP2Heat Shield Requirements for Horizontal Termination Must adhere to pipe clearances Colinear to Coaxial Adapter Must adhere to pipe clearances Alternate built-in options Minimum construction requirementsLink Adapter SLP-TVHWMinimum Total Maximum TotalNON-COMBUSTIBLE Base Under Unit Flue Starter Plate Gas Information Gas ConnectionIntelliFire PlusTM Ignition System Wiring Wiring RequirementsElectrical Information Optional Accessories Requirements Fan Wiring DiagramREM300-HNG-AU Instructions Kit ContentsInstallation Precautions Fireplace Specific InformationChanging Temperature Scale Installation of Remote Control HousingFan Installation AUX300CE Module InstallationProgramming the RC300AU to the Control Module Display Screen Idle When Remote is in on ModeStandby mode Function ButtonsAdjusting Flame Height About on ModeAbout OFF Mode Adjusting Fan SpeedSetting the Child Lock Adjusting ThermostatAdjusting Timer Power OutageFrequently Asked Questions/Troubleshooting Symptom Possible Cause Corrective ActionFinishing Clearances to Mantels or other Combustibles above ApplianceAppliance Setup Install the Log Assembly Pilot AS Sembly LOG PIN Grate TinesCorner LOG Flush With LOG TAB For LOG #6Air Shutter Settings Air Shutter SettingLatches Required to Complete Insert Installation Decorative Fronts and SurroundsOptional RC300AU Remote Optional BRICK-SI30 Kit Optional AccessoriesIPI+ Symptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System If the pilot continues Maintenance Tasks Inspect Maintenance TasksReference Materials Appliance Dimension DiagramModel Dimensions SUPREME-I30-AUMetal Insert, IPI Service PartsLog Set Assembly Description Comments Part Number#15 Valve Assembly SUPREME-N-I30AU, SUPREME-P-I30AU Contact Information

SUPREME-P-I30AU, SUPREME-N-I30AU specifications

The Heat & Glo LifeStyle SUPREME-P-I30AU and SUPREME-N-I30AU are premium gas fireplaces designed to create a cozy, inviting atmosphere while offering modern technological features and exceptional performance. These units are perfect additions to any home, blending elegance with practicality.

One of the standout features of the SUPREME series is its versatile design. The fireplaces are available in both linear and traditional styles, allowing homeowners to choose the configuration that best complements their living space. With a sleek, modern aesthetic, the SUPREME-P-I30AU offers a panoramic view of the flames, making it a captivating focal point in any room.

These models are equipped with advanced heating capabilities. The powerful heat output ensures that the fireplace can effectively warm spaces ranging from medium to large. Homeowners can enjoy optimal comfort during the colder months, knowing they have a reliable source of heat at their disposal.

Another key characteristic is the innovative IntelliFire technology, which automates the ignition system and monitors the flame to ensure safe and efficient operation. This feature not only enhances the user experience but also minimizes energy consumption by allowing the unit to alternate between different flame settings based on the home's heating needs.

Installation is made easy with the SUPREME series, thanks to its flexible venting options. The fireplaces can be vented either vertically or horizontally, making them suitable for various home layouts. Additionally, the units are designed for easy access to components, simplifying maintenance and ensuring longevity.

Both the SUPREME-P-I30AU and SUPREME-N-I30AU come with a range of aesthetic options for customization, including different media choices such as logs, glass, and stones. This allows users to tailor the appearance of their fireplace to match their personal style and home décor.

Safety features are paramount in the design of the SUPREME series. The fireplaces include advanced safety controls and thermal sensors to prevent overheating and ensure peace of mind for users.

In summary, the Heat & Glo LifeStyle SUPREME-P-I30AU and SUPREME-N-I30AU stand out due to their stylish designs, powerful heating capabilities, innovative technologies, and customizable options, making them ideal choices for anyone looking to enhance their home with a functional and aesthetically pleasing gas fireplace.