7 Installation Preparation

Prepare the existing solid fuel masonry or factory built non-combustible firebox for installation.

A. Inspection and Cleaning

Prior to installing the gas insert:

Have the chimney and adjacent structure inspected and cleaned by qualified professionals. Hearth & Home Technologies recommends that NFI, CSIA or AS5601 certified professionals, or technicians under the direction of certified professionals, conduct a minimum of a NFPA 211 Level 2 inspection of the chimney.

Replace component parts of the chimney and fireplace as specified by the professionals.

Ensure all joints are properly engaged and the chimney is properly secured.

Ensure combustible mantel and surround clearances comply with applicable codes and regulations for solid- fuel fireplaces. In the absence of local or regional codes, refer to NFPA 211 or AS5601.

Ensure chimney is constructed of non-combustible materials.

Ensure chimney is clean and in good working order.

Ensure that all chimney cleanouts fit properly to prevent air leakage into chimney.

B. Flue Damper

Fully lock the solid fuel fireplace’s flue damper in the open position, OR completely remove it.

C. Gas Line

Note: If the factory built fireplace has no gas access hole provided, an access hole of 1 in. (25 mm) diameter or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship - like manner. This access hole must be plugged with non-combustible insulation after the gas supply line has been installed.

Install gas line into firebox cavity.

Check local codes and gas line sizing requirements AS5601. Australian Plumber’s Code applies.

It is recommended that extra length of gas line be installed within the existing wood burner or masonry fireplace to allow removal of the insert for future servicing needs.

An in-line regulator MUST be installed if the gas pressure exceeds 3.4 kPa. Failure to install a regulator could dam- age valve.

D. Fireplace Conversion Notice

Permanently attach the label with the following warning to the inside lower back of the fireplace firebox into which the insert is being installed. Silicone or mechanical fasteners may be required to properly secure the label.

WARNING! Risk of Fire! This fireplace has been con- verted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.

E. Electrical Outlet Box

An outlet box may be installed in a bottom back corner of the existing solid fuel masonry or factory built fireplace to power the appliance. Each unit ships standard with a cord assembly to permit blowers or other optional accessories to be used. The accessories plug may into the new outlet box or be routed out onto the hearth to a nearby outlet.

F. Remote Control

IPI Models:

If a remote control kit is used to control blower function, the AUX300CE module can only be placed in the control cavity to the right of the control panel. See Figure 7.1.

AUX300CE MODULE

Figure 7.1 Location of AUX300CE for Remote Control Blower Function - IPI

22

Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU2222-900 Rev. P • 6/12

Image 22
Contents What to do if you smell gas Models SUPREME-N-I30AU SUPREME-P-I30AUSAI Global Ref No GSCS20181 HOT SurfacesMODELSSupreme-N-I30AU,Supreme-P-I30AU Congratulations Homeowner Reference InformationTable of Contents User GuideAustralian Warranty Information Limited Lifetime WarrantyOther Rights Perth Listing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace IPI Battery Tray/Battery Installation Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceNine Hour Safety Shutdown Feature Module ResetBefore Lighting Fireplace What to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveIssue Solutions Frequently Asked QuestionsAfter Appliance is Lit Maintenance and Service Logs Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection FireboxGetting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Fireplace Size Requirements Minimum Fireplace OpeningTOP View Front View Side View Fireplace OpeningMantel and Wall Projections SUPREME-I30AUTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Vent Limits Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsPage Placing, Securing and Leveling Appliance Factory Built Installing Adaptor and Termination CapMasonry Damper Flashing Kit OptionalModel Flue Termination Approval Direct Vent Flex Liner Accessory Kits Vent Kits ComponentsFlue Termination For Horizontal Terminations using the SLP-TRAP2Heat Shield Requirements for Horizontal Termination Must adhere to pipe clearances Colinear to Coaxial Adapter Must adhere to pipe clearances Alternate built-in options Minimum construction requirementsLink Adapter SLP-TVHWMinimum Total Maximum TotalNON-COMBUSTIBLE Base Under Unit Flue Starter Plate Gas Information Gas ConnectionIntelliFire PlusTM Ignition System Wiring Wiring RequirementsElectrical Information Optional Accessories Requirements Fan Wiring DiagramREM300-HNG-AU Instructions Kit ContentsInstallation Precautions Fireplace Specific InformationChanging Temperature Scale Installation of Remote Control HousingFan Installation AUX300CE Module InstallationProgramming the RC300AU to the Control Module Display Screen Idle When Remote is in on ModeStandby mode Function ButtonsAdjusting Flame Height About on ModeAbout OFF Mode Adjusting Fan SpeedSetting the Child Lock Adjusting ThermostatAdjusting Timer Power OutageFrequently Asked Questions/Troubleshooting Symptom Possible Cause Corrective ActionFinishing Clearances to Mantels or other Combustibles above ApplianceAppliance Setup Install the Log Assembly Pilot AS Sembly LOG PIN Grate TinesCorner LOG Flush With LOG TAB For LOG #6Air Shutter Settings Air Shutter SettingLatches Required to Complete Insert Installation Decorative Fronts and SurroundsOptional RC300AU Remote Optional BRICK-SI30 Kit Optional AccessoriesIPI+ Symptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System If the pilot continues Maintenance Tasks Inspect Maintenance TasksReference Materials Appliance Dimension DiagramModel Dimensions SUPREME-I30-AUMetal Insert, IPI Service PartsLog Set Assembly Description Comments Part Number#15 Valve Assembly SUPREME-N-I30AU, SUPREME-P-I30AU Contact Information

SUPREME-P-I30AU, SUPREME-N-I30AU specifications

The Heat & Glo LifeStyle SUPREME-P-I30AU and SUPREME-N-I30AU are premium gas fireplaces designed to create a cozy, inviting atmosphere while offering modern technological features and exceptional performance. These units are perfect additions to any home, blending elegance with practicality.

One of the standout features of the SUPREME series is its versatile design. The fireplaces are available in both linear and traditional styles, allowing homeowners to choose the configuration that best complements their living space. With a sleek, modern aesthetic, the SUPREME-P-I30AU offers a panoramic view of the flames, making it a captivating focal point in any room.

These models are equipped with advanced heating capabilities. The powerful heat output ensures that the fireplace can effectively warm spaces ranging from medium to large. Homeowners can enjoy optimal comfort during the colder months, knowing they have a reliable source of heat at their disposal.

Another key characteristic is the innovative IntelliFire technology, which automates the ignition system and monitors the flame to ensure safe and efficient operation. This feature not only enhances the user experience but also minimizes energy consumption by allowing the unit to alternate between different flame settings based on the home's heating needs.

Installation is made easy with the SUPREME series, thanks to its flexible venting options. The fireplaces can be vented either vertically or horizontally, making them suitable for various home layouts. Additionally, the units are designed for easy access to components, simplifying maintenance and ensuring longevity.

Both the SUPREME-P-I30AU and SUPREME-N-I30AU come with a range of aesthetic options for customization, including different media choices such as logs, glass, and stones. This allows users to tailor the appearance of their fireplace to match their personal style and home décor.

Safety features are paramount in the design of the SUPREME series. The fireplaces include advanced safety controls and thermal sensors to prevent overheating and ensure peace of mind for users.

In summary, the Heat & Glo LifeStyle SUPREME-P-I30AU and SUPREME-N-I30AU stand out due to their stylish designs, powerful heating capabilities, innovative technologies, and customizable options, making them ideal choices for anyone looking to enhance their home with a functional and aesthetically pleasing gas fireplace.