C. Optional Accessories Requirements

This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control.

To connect optional accessories, the supplied cord as- sembly should be used. See attached Figure 10.2 for a wiring diagram for a blower or remote.

Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories.

Plug the cord into a convenient outlet.

Must use cord supplied.

An IntelliFire Plus™ Wireless Control or WSK-21 wired wall switch may be used with the IntelliFire Plus™ Igni- tion System.

A standard ON/OFF switch is compatible.

WARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING! Risk of Shock! Replace damaged wire with type 105 °C (221 °F) rated wire. Wire must have high temperature insulation.

GROUND

TERMINATIONSWITCHED DC REGULATOR

2166-305

NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105° C RATED WIRE.

NOTE: USE ZIP TIES TO RESTRAIN THE LOOSE WIRES UNDERNEATH THE APPLIANCE AND KEEP THEM AWAY FROM THE BLOWER WHEEL (FAN BLADES).

POWER CORD ASM 2222-374

PILOT OPTIONS

FAN ASSEMBLY

NG 2090-012

GFK210-240V

LP 2090-013

 

GAS TUBE

 

 

 

FLAME

 

IGNITOR

 

 

 

 

SENSE

 

 

 

MODULE (GRAY)

 

 

 

2166-306

WHITE

ORANGE

 

 

AUX300 MODULE

 

 

 

 

 

TO VALVE

2166-340

 

 

 

AUX1 AUX2

WIRE HARNESS 2166-304

FLAME

MODULATION

ORANGE (PILOT)

GROUND* RED

BATTERY PACK ASSEMBLY 4067-223

BLACK

VALVE OPTIONS

NG 2166-302

LP 2166-303

Figure 10.2 Fan Wiring Diagram

JUMPER WIRE RED

OPTIONAL

WALL SWITCH

2187-198

OR

GREEN

SURROUND

(MAIN)

SWITCH

* NOTE: GROUND FROM WIRE HARNESS MUST BE ATTACHED TO UNPAINTED METAL

38

Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU2222-900 Rev. P • 6/12

Image 38
Contents What to do if you smell gas Models SUPREME-N-I30AU SUPREME-P-I30AUSAI Global Ref No GSCS20181 HOT SurfacesMODELSSupreme-N-I30AU,Supreme-P-I30AU Congratulations Homeowner Reference InformationTable of Contents User GuideAustralian Warranty Information Limited Lifetime WarrantyOther Rights Perth Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide IPI Battery Tray/Battery Installation Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceBefore Lighting Fireplace Module ResetNine Hour Safety Shutdown Feature What to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveAfter Appliance is Lit Frequently Asked QuestionsIssue Solutions Maintenance and Service Logs Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection FireboxGetting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Fireplace Size Requirements Minimum Fireplace OpeningTOP View Front View Side View Fireplace OpeningMantel and Wall Projections SUPREME-I30AUTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Vent Limits Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsPage Placing, Securing and Leveling Appliance Factory Built Installing Adaptor and Termination CapMasonry Damper Flashing Kit OptionalModel Flue Termination Approval Direct Vent Flex Liner Accessory Kits Vent Kits ComponentsHeat Shield Requirements for Horizontal Termination For Horizontal Terminations using the SLP-TRAP2Flue Termination Must adhere to pipe clearances Colinear to Coaxial Adapter Must adhere to pipe clearances Alternate built-in options Minimum construction requirementsLink Adapter SLP-TVHWMinimum Total Maximum TotalNON-COMBUSTIBLE Base Under Unit Flue Starter Plate Gas Information Gas ConnectionElectrical Information Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Optional Accessories Requirements Fan Wiring DiagramREM300-HNG-AU Instructions Kit ContentsInstallation Precautions Fireplace Specific InformationChanging Temperature Scale Installation of Remote Control HousingProgramming the RC300AU to the Control Module AUX300CE Module InstallationFan Installation Display Screen Idle When Remote is in on ModeStandby mode Function ButtonsAdjusting Flame Height About on ModeAbout OFF Mode Adjusting Fan SpeedSetting the Child Lock Adjusting ThermostatAdjusting Timer Power OutageFrequently Asked Questions/Troubleshooting Symptom Possible Cause Corrective ActionFinishing Clearances to Mantels or other Combustibles above ApplianceAppliance Setup Install the Log Assembly Pilot AS Sembly LOG PIN Grate TinesCorner LOG Flush With LOG TAB For LOG #6Latches Air Shutter SettingAir Shutter Settings Required to Complete Insert Installation Decorative Fronts and SurroundsIPI+ Optional AccessoriesOptional RC300AU Remote Optional BRICK-SI30 Kit IntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action If the pilot continues Maintenance Tasks Inspect Maintenance TasksReference Materials Appliance Dimension DiagramModel Dimensions SUPREME-I30-AUMetal Insert, IPI Service PartsLog Set Assembly Description Comments Part Number#15 Valve Assembly SUPREME-N-I30AU, SUPREME-P-I30AU Contact Information

SUPREME-P-I30AU, SUPREME-N-I30AU specifications

The Heat & Glo LifeStyle SUPREME-P-I30AU and SUPREME-N-I30AU are premium gas fireplaces designed to create a cozy, inviting atmosphere while offering modern technological features and exceptional performance. These units are perfect additions to any home, blending elegance with practicality.

One of the standout features of the SUPREME series is its versatile design. The fireplaces are available in both linear and traditional styles, allowing homeowners to choose the configuration that best complements their living space. With a sleek, modern aesthetic, the SUPREME-P-I30AU offers a panoramic view of the flames, making it a captivating focal point in any room.

These models are equipped with advanced heating capabilities. The powerful heat output ensures that the fireplace can effectively warm spaces ranging from medium to large. Homeowners can enjoy optimal comfort during the colder months, knowing they have a reliable source of heat at their disposal.

Another key characteristic is the innovative IntelliFire technology, which automates the ignition system and monitors the flame to ensure safe and efficient operation. This feature not only enhances the user experience but also minimizes energy consumption by allowing the unit to alternate between different flame settings based on the home's heating needs.

Installation is made easy with the SUPREME series, thanks to its flexible venting options. The fireplaces can be vented either vertically or horizontally, making them suitable for various home layouts. Additionally, the units are designed for easy access to components, simplifying maintenance and ensuring longevity.

Both the SUPREME-P-I30AU and SUPREME-N-I30AU come with a range of aesthetic options for customization, including different media choices such as logs, glass, and stones. This allows users to tailor the appearance of their fireplace to match their personal style and home décor.

Safety features are paramount in the design of the SUPREME series. The fireplaces include advanced safety controls and thermal sensors to prevent overheating and ensure peace of mind for users.

In summary, the Heat & Glo LifeStyle SUPREME-P-I30AU and SUPREME-N-I30AU stand out due to their stylish designs, powerful heating capabilities, innovative technologies, and customizable options, making them ideal choices for anyone looking to enhance their home with a functional and aesthetically pleasing gas fireplace.