Heat & Glo LifeStyle SUPREME-N-I30AU, SUPREME-P-I30AU Before Lighting Fireplace, Module Reset

Page 11

4.If you intend to use both an optional wired wall switch and the RC300 remote control to operate your fireplace, the wall switch will override any commands given by the remote.

 

MODULO

 

 

INTERRUPTOR

 

DE SELECCIÓN

INTERRUPTOR

LUZ INDICADORA

LP/NG GAS DE

DE LA LLAMA

DEL ESTADO

INTERRUPTOR DE

ALTA/BAJA (HI/LOW)

 

SELECCIÓN

Figure 2.3 Control Module

5.Module Reset

This module may lock-out under certain conditions. When this occurs, the appliance will not ignite or respond to commands. The module will go into lock-out mode by emitting three audible beeps, then continuously displaying an error code at its status indicator LED.

Check battery tray. Remove batteries if installed. Batteries should only be installed for use during power outages. See Section G.

Locate the module selector switch. (See Figure 2.3).

Set the module selector switch to the OFF position.

Wait five (5) minutes to allow possible accumulated gas to clear.

Set the module selector switch to ON or REMOTE position.

Start the appliance.

WARNING! Risk of Explosion! DO NOT press the mod- ule reset switch more than one time within a five minute time period. Gas may accumulate in firebox. Call a quali- fied service technician.

Note: If the module is in LOCK-OUT mode, resetting the circuit breaker to the appliance will also reset the module.

Note: For units installed in Australia, the residence’s 220/240 wall outlet to which this appliance’s power cord is connected, must be wired to an in-line on/off switch. This is required for servicing and/or resetting the control module in the event of a control module LOCK-OUT.

Nine Hour Safety Shutdown Feature

This appliance has a safety feature that automatically shuts down the fireplace after 9 hours of continuous operation without receiving a command from the wall switch or optional remote.

I. Before Lighting Fireplace

Before operating this fireplace for the first time, have a qualified technician:

Verify all shipping materials have been removed from inside and/or underneath the firebox.

Review proper placement of logs, ember material and/ or other decorative materials.

Check the wiring.

Check the air shutter adjustment.

Ensure that there are no gas leaks.

Ensure that the glass is sealed and in the proper position and that the integral barrier is in place.

WARNING! Risk of Fire/Asphyxiation! DO NOT oper-

ate fireplace with fixed glass assembly removed.

Determine if this fireplace has a standing pilot or an Intellifire ignition system. Ask your dealer or open control access panel, look at gas valve.

A standing pilot ignition will have a red or black ignitor button (refer to Figure 2.4).

An Intellifire ignition system will not have a button.

RED OR BLACK IGNITOR BUTTON

Figure 2.4 Ignitor Button

Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU2222-900 Rev. P • 6/12

11

Image 11
Contents HOT Surfaces Models SUPREME-N-I30AU SUPREME-P-I30AUSAI Global Ref No GSCS20181 What to do if you smell gasMODELSSupreme-N-I30AU,Supreme-P-I30AU Homeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Australian Warranty InformationOther Rights Perth Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches IPI Battery Tray/Battery InstallationBefore Lighting Fireplace Module ResetNine Hour Safety Shutdown Feature GAS Valve Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASAfter Appliance is Lit Frequently Asked QuestionsIssue Solutions Maintenance and Service Firebox Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection LogsTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Minimum Fireplace Opening Fireplace Size RequirementsFireplace Opening TOP View Front View Side ViewSUPREME-I30AU Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceConnecting Vent Pipe Vent LimitsPage Placing, Securing and Leveling Appliance Damper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory BuiltModel Flue Termination Approval Vent Kits Components Direct Vent Flex Liner Accessory KitsHeat Shield Requirements for Horizontal Termination For Horizontal Terminations using the SLP-TRAP2Flue Termination Must adhere to pipe clearances Colinear to Coaxial Adapter Must adhere to pipe clearances Minimum construction requirements Alternate built-in optionsMaximum Total SLP-TVHWMinimum Total Link AdapterNON-COMBUSTIBLE Base Under Unit Flue Starter Plate Gas Connection Gas InformationElectrical Information Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Fan Wiring Diagram Optional Accessories RequirementsFireplace Specific Information Kit ContentsInstallation Precautions REM300-HNG-AU InstructionsInstallation of Remote Control Housing Changing Temperature ScaleProgramming the RC300AU to the Control Module AUX300CE Module InstallationFan Installation Function Buttons Idle When Remote is in on ModeStandby mode Display ScreenAdjusting Fan Speed About on ModeAbout OFF Mode Adjusting Flame HeightPower Outage Adjusting ThermostatAdjusting Timer Setting the Child LockSymptom Possible Cause Corrective Action Frequently Asked Questions/TroubleshootingClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Pilot AS Sembly LOG PIN Grate Tines Install the Log AssemblyFor LOG #6 Corner LOG Flush With LOG TABLatches Air Shutter SettingAir Shutter Settings Decorative Fronts and Surrounds Required to Complete Insert InstallationIPI+ Optional AccessoriesOptional RC300AU Remote Optional BRICK-SI30 Kit IntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action If the pilot continues Inspect Maintenance Tasks Maintenance TasksSUPREME-I30-AU Appliance Dimension DiagramModel Dimensions Reference MaterialsDescription Comments Part Number Service PartsLog Set Assembly Metal Insert, IPI#15 Valve Assembly SUPREME-N-I30AU, SUPREME-P-I30AU Contact Information

SUPREME-P-I30AU, SUPREME-N-I30AU specifications

The Heat & Glo LifeStyle SUPREME-P-I30AU and SUPREME-N-I30AU are premium gas fireplaces designed to create a cozy, inviting atmosphere while offering modern technological features and exceptional performance. These units are perfect additions to any home, blending elegance with practicality.

One of the standout features of the SUPREME series is its versatile design. The fireplaces are available in both linear and traditional styles, allowing homeowners to choose the configuration that best complements their living space. With a sleek, modern aesthetic, the SUPREME-P-I30AU offers a panoramic view of the flames, making it a captivating focal point in any room.

These models are equipped with advanced heating capabilities. The powerful heat output ensures that the fireplace can effectively warm spaces ranging from medium to large. Homeowners can enjoy optimal comfort during the colder months, knowing they have a reliable source of heat at their disposal.

Another key characteristic is the innovative IntelliFire technology, which automates the ignition system and monitors the flame to ensure safe and efficient operation. This feature not only enhances the user experience but also minimizes energy consumption by allowing the unit to alternate between different flame settings based on the home's heating needs.

Installation is made easy with the SUPREME series, thanks to its flexible venting options. The fireplaces can be vented either vertically or horizontally, making them suitable for various home layouts. Additionally, the units are designed for easy access to components, simplifying maintenance and ensuring longevity.

Both the SUPREME-P-I30AU and SUPREME-N-I30AU come with a range of aesthetic options for customization, including different media choices such as logs, glass, and stones. This allows users to tailor the appearance of their fireplace to match their personal style and home décor.

Safety features are paramount in the design of the SUPREME series. The fireplaces include advanced safety controls and thermal sensors to prevent overheating and ensure peace of mind for users.

In summary, the Heat & Glo LifeStyle SUPREME-P-I30AU and SUPREME-N-I30AU stand out due to their stylish designs, powerful heating capabilities, innovative technologies, and customizable options, making them ideal choices for anyone looking to enhance their home with a functional and aesthetically pleasing gas fireplace.