CONTENTS

Important Owner Information

i

All Models

17

Introduction

i

Pressure & Temperature Relief Valves

19

Important Safety Information

1

Pressure Reducing Valve

20

Model Description

4

Temperature/Pressure Gauges

20

All Models

4

Blended Phosphate Water

 

 

Imperial Models “S” Series

4

Treatment System (Optional)

20

Compact Models “C” Series

4

Plumbing Connections

20

Mini-Compact Models “MC” Series

4

Electrical-All Sizes and Voltages

25

Specifications

5

Operation

26

Circuit Breaker & Fused Disconnect

 

System Start-up

26

Switch Sizes

5

Shut Down

24

Sizing Chart for Low-Temp Dishmachines

8

Maintenance

26

Booster Heater Sizing Chart

10

General

27

Capacity Charts

14

Accessories

29

Dimensions

15

Troubleshooting

30

Installation

16

Hatco Limited Warranty

34

Location

16

Authorized Parts Distributors

Back Cover

IMPORTANT OWNER INFORMATION

Record the model number, serial number (identification decal located on the unit), voltage and purchase date of your Electric Booster Water Heater in the spaces below. Please have this information available when calling Hatco for service assistance.

Model No. ________________________________

Business

8:00 a.m. to 5:00 p.m.

Hours:

Central Standard Time

 

(Summer Hours: June to September –

 

8:00 a.m. to 5:00 p.m. C.D.T.

 

Monday through Thursday

 

8:00 a.m. to 2:30 p.m. C.D.T. Friday)

Telephone: (800) 558-0607; (414) 671-6350

Serial No. ________________________________

Voltage __________________________________

Date of Purchase __________________________

INTRODUCTION

Fax:

(800)

690-2966

(Parts & Service)

 

(414)

671-3976

(International)

24-Hour 7-Day Parts & Service Assistance available in the United States and Canada by calling (800) 558-0607.

Additional information can be found by visiting our web site at www.hatcocorp.com

Hatco Electric Booster Water Heaters are designed for use with commercial dishwashers to boost the temperature of the regularly available hot water, usually 110°-150°F (43°-66°C) up to 180°F (82°C). Water at 180°F (82°C) can be used as sanitizing rinse water in commercial dishwashers in accordance with Health Codes, NSF Standard #5 and plumbing codes.

All Hatco Booster Heaters are ready for electrical and plumbing service connections, with a pre-set ambient compensated immersion thermostat(s) and a high temperature limit switch. The service area is accessible from the front of the unit, permitting easy installation.

This manual provides the installation, safety and operating instructions for the Booster Heaters. We recommend all installation, operating and safety

instructions appearing in this manual be read prior to installation or operation of your Booster Heaters. Safety instructions that appear in this manual after a

warning symbol and the words WARNING or CAUTION printed in bold face are very important. WARNING means there is the possibility of serious personal injury or death to yourself or others. CAUTION means there is the possibility of minor or moderate injury. CAUTION without the symbol signifies the possibility of equipment or property damage only.

Hatco Electric Booster Water Heaters are a product of extensive research and field testing. The materials used were selected for maximum durability, attractive appearance and optimum performance. Every unit is thoroughly inspected and tested prior to shipment.

Form No. EBOOSTERM-0406

i

Image 2
Contents Electric Booster Water Heaters Introduction ContentsImportant Owner Information Important Safety Information Important Safety Information Important Safety Information Imperial Models S Series Model DescriptionsALL Models Compact Models C SeriesSpecifications Circuit Breaker & Fused Disconnect Switch Sizes 4 to 12 kWVolts Phase Amp Draw Breaker or Copper N d u i t Fuse Size Wire SizeCircuit Breaker & Fused Disconnect Switch Sizes 36 to 57 kW Sizing Chart for LOW-TEMP Dishmachines Boosters Rated AT 30F 16C RiseSpecifications Booster Heater Sizing Chart Electric Compact Booster Imperial BoosterWM-5C FW4 Stpc Stpcw Capacity Compact C Series Model 40F 22C Rise 70F 39C Rise Shipping WeightCapacity Imperial S Series Capacity MINI-COMPACT MC SeriesDimensions Imperial S Series Location InstallationDimensions MINI-COMPACT MC Series Installing Legs Leg Pressure Reducing Valve Temperature/Pressure GaugeTemperature Pressure Relief Valve Mounting Brackets with HardwarePressure and Temperature Relief Valves For Installing PressureBlended Phosphate Water Treatment System Optional TEMPERATURE/PRESSURE GaugesPressure Reducing Valve Plumbing ConnectionsInlet Refer to , 9, 10, 11 orPlumbing Connections Imperial S Series Form No. EBOOSTERM-0406 Outlet ELECTRICAL-ALL Sizes and Voltages GeneralShut Down OperationSystem START-UP Thermostat Adjustment MaintenanceHigh Temperature Limit Safety Switch GeneralBlended Phosphate Treatment System Optional Floor Mounting Hardware AccessoriesStainless Steel Adjustable Legs Shock AbsorberTroubleshooting Symptom Probable Cause Corrective Action Troubleshooting Troubleshooting Hatco Limited Warranty Product WarrantyForm No. EBOOSTERM-0406 Form No. EBOOSTERM-0406 Form No. EBOOSTERM-0406 Hatco Authorized Parts Distributors